This text of 3 T.C.A. 260 (General Electric Technical Services Co. v. Autoridad de Energia Electrica Recurrida) is published on Counsel Stack Legal Research, covering Tribunal De Apelaciones De Puerto Rico/Court of Appeals of Puerto Rico primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
General Electric Technical Services Co. v. Autoridad de Energia Electrica Recurrida, 3 T.C.A. 260, 97 DTA 137 (prapp 1997).

Opinion

Brau Ramírez, Juez Ponente

TEXTO COMPLETO DE LA SENTENCIA

I

El presente recurso de revisión administrativa fue originalmente presentado ante el Tribunal de Primera Instancia, Sala Superior de San Juan, y posteriormente referido a este Tribunal, conforme a lo dispuesto por el art. 9.004, subinciso (a), de Ley de la Judicatura de Puerto Rico de 1994, según enmendada por la Ley Núm. 248 de 25 de diciembre de 1995.

La parte recurrente, General Electric Technical Services Co., Inc. ("General Electric"), solicita la revisión de una resolución emitida el 22 de noviembre de 1995 por la Secretaría de Procedimientos Adjudicativos de la agencia recurrida Autoridad de Energía Eléctrica de Puerto Rico ("A.E.E."). Mediante el dictamen en cuestión, la A.E.E. denegó la impugnación de subasta presentada por la recurrente y confirmó, de este modo, la decisión original de la A.E.E. de adjudicar la Subasta LJ-04970, sobre el proyecto Repotentación Unidades 5 y 6 de la Central Termoeléctrica de San Juan, a la corporación española recurrida Abengoa S.A. c/o Passco, Inc. ("ABENGOA").

Confirmamos la resolución recurrida.

II

Según se desprende del recurso, durante el mes de agosto de 1994, la A.E.E. anunció la Subasta LJ-04970 para el proyecto denominado "Repotentación Unidades 5 y 6 de la Central Termoeléctrica de San Juan". Dicho proyecto tiene el propósito de reemplazar dos (2) unidades de 44 megavatios (MW) de la planta ubicada en el área portuaria de Puerto Nuevo, adyacente a la Bahía de San Juan, por una planta de ciclo combinado consistente de dos (2) turbinas de gas en combinación con dos (2) turbinas de vapor con calderas de recuperación de calor para la generación de vapor, que añadirán más [262]*262de 370 MW de capacidad al sistema eléctrico de la Central de San Juan.

El 20 de septiembre de 1994 se celebró la reunión pre-subasta en la cual participaron las siguientes compañías: Maxon Engineering; ABB/Isidro Ramos; Flour Daniel Caribbean, Inc.; General Electric; Westinghouse Electric; Black & Veacth International; Bechtel; Foster Wheeler; Gilbert Commonwealth; Stone & Webster; R.G. Engineering; Distral de Puerto Rico; Abengoa S.A., c/o Passco, Inc.; National Power Div.; Badcock & Wilcox Española S.A.; y Kiewitt. Posteriormente, varias de estas compañías se unieron en consorcios.

El 23 de noviembre de 1994 se efectuó el acto de apertura de la subasta en el cual participaron ABENGOA; GETSO, consorcio formado por General Electric y Raytheon Cathalytic, Inc.; Badcock & Wilcox Española, S.A.; Kiewitt Industrial Co.; A.B.B./Metric Constructors; Black &\Veatch International; y Flour Daniel Caribbean, Inc.

La A.E.E. creó un Comité Evaluador ("el Comité") con el fin de evaluar las ofertas sometidas por las compañías anteriormente mencionadas. El proceso de evaluación se realizó en dos (2) etapas. En la primera, se determinó cuáles ofertas cumplían con los requisitos básicos del proyecto. Aquellas compañías que pasaron dicha etapa fueron sometidas a la segunda etapa de evaluación en. la cual se determinó cuál oferta era la mejor y la más beneficiosa para la A.E.E. Durante el mencionado período de evaluación, el Comité solicitó de todas las compañías que participaron en la subasta distintas aclaraciones de sus respectivas ofertas. Mediante carta suscrita el 20 de enero de 1995, el Comité solicitó a ABENGOA la siguiente información:

"7. Please specify the manufacturer for the Combustion Turbine to be supplied.
2.Please clarify your proposal's Condenser Circulation Cooling Water System. Your clarification should include all flows, equipment, and their specific location that will be installed to meet the cooling water temperature requirement.
3.Please clarify the apparent conflict between Volume B (Page 8-A j and Volume C (Table 6, Section 17.3) in regard to the Selective Catalytic Reduction Equipment of your proposal. In Volume B the price for the system is specified as being optional while in Volume C it is stated that the price quoted for the equipment should be deducted from the bid price.
4.In various places of your proposal, the opacity values for the combustion turbine are identified. Please specify what opacity level is being guaranteed in your proposal and where such guarantee is stated."

ABENGOA contestó dicha misiva el 27 de enero de 1995 señalando que:

"7. The Combustion Turbine manufacturer is to be Westinghouse Electric Corp., model 501F.
2. Our proposal is a turn key job for two (2) combined cycle power sets in which we provided overall performance output, efficiency and emission values; therefore, the limitations stated by you of 50,000 gpm can be achieved. ABENGOA's proposal meets in full the sea water cooling flow limitations for the rated heat balance given in our proposal. Attached hereto you will find the calculations and number of heat exchangers to be installed in the rooftop area of the generators to be removed, to comply with the 12' F limitation. We have guarantee from Westinghouse for the performance of the 501F Combustion Turbines, which exceed the 4,000 fired hours required in the specifications, and we will decide the final number of cooling heat exchanges after the performanced tests are carried out in the open cycle operations, without delaying the schedule and with PREP A's acceptance of the calculations.
3. The price of $ 2,378,475 given in the cover letter of our proposal clearly indicates this is an adder for each unit, if the Federal Agencies require it, and this offer supersedes any other discrepancies.
4. The opacity quarantee is 20% or less for the operating conditions, with 10% to 20% values typical for number 2 oil firing..."

[263]*263El 7 de abril de 1995, el Comité presentó una evaluación económica de las propuestas de ABENGOA, GETSO y Kiewtt-ABB y Kiewtt-GE. Para dicha evaluación, se utilizó el programa computarizado "PROSCREEN", mediante el cual se evaluaron las posibles alternativas futuras para suplir la demanda, y como resultado se obtuvieron diferentes planes de expansion ordenados en forma ascendente a base de los costos totales.

Además, se tomaron en consideración los siguientes parámetros: "heat rate", costo de combustible, capacidad, costos de operación y mantenimiento, entre otros, tanto de las unidades existentes como futuras.

En torno al factor de capacidad anual mayor a lo largo de la vida esperada de las unidades o el equipo, en la mencionada evaluación se presumió que era equivalente a un 75% para todas las alternativas incluyendo el efecto del mantenimiento y la tasa de avería forzada. Los costos de operación y mantenimiento fijo y variable se basaron en unidades típicas de ciclo combinado del informe "Technology Characterization Resource Planning Assumptions". Tanto los costos de operación fijo ($kw) como el variable (0kwh) se ajustaron debido a las diferencias en capacidades de las propuestas.

La mencionada evaluación económica determinó que la propuesta menor era de ABENGOA y recomendaba que la subasta fuese adjudicada a dicho consorcio. Expresaba:

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Benítez Rexach v. Municipio de Bayamón
43 P.R. Dec. 734 (Supreme Court of Puerto Rico, 1932)
Junta de Relaciones del Trabajo v. International Longshoremen Ass'n
73 P.R. Dec. 616 (Supreme Court of Puerto Rico, 1952)
Justiniano v. Estado Libre Asociado
100 P.R. Dec. 334 (Supreme Court of Puerto Rico, 1971)
Cancel Acevedo v. Municipio de San Juan y Stadium & Coliseum Operators, Inc.
101 P.R. Dec. 296 (Supreme Court of Puerto Rico, 1973)
Murphy Bernabe v. Tribunal Superior de Puerto Rico
103 P.R. Dec. 692 (Supreme Court of Puerto Rico, 1975)
Rubin Ramírez v. Trías Monge
111 P.R. Dec. 481 (Supreme Court of Puerto Rico, 1981)
Continental Construction Corp. v. Municipio de Bayamón
115 P.R. Dec. 559 (Supreme Court of Puerto Rico, 1984)
Díaz Marín v. Municipio de San Juan
117 P.R. Dec. 334 (Supreme Court of Puerto Rico, 1986)
López Vives v. Policía de Puerto Rico
118 P.R. Dec. 219 (Supreme Court of Puerto Rico, 1987)
Mar-Mol Co. v. Administración de Servicios Generales
126 P.R. Dec. 864 (Supreme Court of Puerto Rico, 1990)

Cite This Page — Counsel Stack

Bluebook (online)
3 T.C.A. 260, 97 DTA 137, Counsel Stack Legal Research, https://law.counselstack.com/opinion/general-electric-technical-services-co-v-autoridad-de-energia-electrica-prapp-1997.