Except as provided in section 76-3505 , new construction built after September 1, 2019, in the State of Nebraska that is intended to be regularly occupied by people shall be built using radon resistant new construction. Such construction shall meet the following minimum standards:

(1)Sumps:
(a)A sump pit open to soil or serving as the termination point for subslab or exterior drain tile loops shall be covered with a gasketed or otherwise sealed lid;
(b)A sump used as the suction point in a subslab depressurization system shall have a lid designed to accommodate the vent pipe; and
(c)A sump used as a floor drain shall have a lid equipped with a trapped inlet;
(2)A passive subslab depressurization system shall be installed during construction in basement or slab-on-grade buildings, inc