§ 25-9-80 — Main Fans

Alabama·Title 25 Industrial Relations and Labor·Ch. 9 Coal Mine Safety·Art. 4 Mine Gases and Ventilation
(a)All main fans shall be installed on the surface, in fireproof housings, the fan situated not less than 30 feet from its air shaft or air course and on one side of the line of such opening so that the fan will not be in direct line of the force of a blast or explosion. The air duct connecting the fan with the mine opening shall be fireproof and provided with self-closing explosion doors.
(b)In mines ventilated with multiple fans, each main fan shall be equipped with fireproof doors automatically closing in the event of a fan failure to prevent air reversal through the fan.
(c)Every main fan installed after August 12, 1949, ventilating a mine classed as gassy, must have an auxiliary drive mechanism that will operate the fan at not less than 80 percent of its regular volume. Dual fan in

Free access — add to your briefcase to read the full text and ask questions with AI

Alabama § 25-9-80 (Main Fans) — published by Counsel Stack Legal Research, free access to 12M+ legal documents.

Legislative History

(Acts 1949, No. 207, p. 242, §13; Acts 1975, 4th Ex. Sess., No. 147, p. 2866, §1.)