Pall Corp. v. Micron Separations, Inc.

792 F. Supp. 1298, 1992 U.S. Dist. LEXIS 5883, 1992 WL 86686
CourtDistrict Court, D. Massachusetts
DecidedApril 24, 1992
DocketCiv. A. 86-1427-Y
StatusPublished
Cited by6 cases

This text of 792 F. Supp. 1298 (Pall Corp. v. Micron Separations, Inc.) is published on Counsel Stack Legal Research, covering District Court, D. Massachusetts primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Pall Corp. v. Micron Separations, Inc., 792 F. Supp. 1298, 1992 U.S. Dist. LEXIS 5883, 1992 WL 86686 (D. Mass. 1992).

Opinion

MEMORANDUM OF DECISION 1

YOUNG, District Judge.

This case involves United States Patent 4,340,479 (the “Pall patent”) covering a process for preparing hydrophilic polyam-ide membrane filtered media and product, which issued on July 20, 1982 to the plaintiff Pall Corporation (“Pall”). Pall is a New York corporation having a principal place of business in Glen Cove, New York, and offices on Route 25A in Roslyn, New York. Pall was founded in the late 1940’s by Dr. David B. Pall of Roslyn Estates, New York. Dr. Pall is designated as the inventor of the patent-in-suit.

The action is brought against the defendant Micron Separations, Inc. (“MSI”), a Massachusetts corporation having a principal place of business in Westborough, Massachusetts. MSI was formed in 1981 when certain employees of a filtration company known as Millipore, specifically James S. Johnson and John M. Greenwood, left that company and, along with Edward J. Ackley, decided to start their own company and enter into competition with Pall, Millipore, and others in the microporous filtration industry.

The complaint in this action was filed on May 7,1986. It seeks a judgment that MSI has willfully infringed the Pall patent. The complaint also seeks damages for past infringement and an injunction against future infringement.

I. Prior Art

A. The general setting.

At this juncture it’s helpful to put some matters in perspective. Polymeric membranes are thin, sheet like materials with very small interconnected pores. The pores usually range in size from about one-tenth of a micron to ten microns. The membranes are made from a chemical ma *1302 terial that has many thousands of repeating units, a polymer. There are many such materials, many methods for making them into membranes, and many uses for such membranes.

Polymeric membranes, in the strictest sense of the word, may be fibrous or non-fibrous. Usually, however, when the term polymeric membrane is employed, the non-fibrous type is meant. Non-fibrous membranes are usually made directly from a solution or melt of the polymer. Fibrous polymeric membranes are made by first converting the polymer into fibers, and then making a thin web from those fibers. Potassium titanate is a good example of a fibrous polymeric membrane.

Prior to the development of the Pall nylon membrane, fibrous filter media, made, for example, from potassium titanate or asbestos, were commonly employed as filtration medium. At the present time, the two most commonly used microfiltration membranes are Pall’s nylon membrane and Millipore’s PVDF membrane, both made from non-fibrous polymers. They are employed mainly in the filtration of liquids to remove very small particles, including bacteria, a process known as microfiltration.

Typical filtration applications include use by pharmaceutical companies to assure that the drugs they make are free of bacteria contamination, use by electronic companies to purify water for chip manufacture, and use by hospitals to assure that the fluids administered to patients are free from bacteria and other contaminants. Typical biotechnological applications include use in diagnostics to detect the presence of antibodies and the so-called transfer membranes for identification of genetic characteristics.

Depending upon their use, polymeric membranes may have a skin on them, or they may be without a skin. Certain processes, reverse osmosis, for example, require the presence of a continuous skin, while in other processes microfiltration, for example, the complete absence of any skin is necessary.

Microfiltration is one of the most common applications for polymeric membranes at this time. It is, however, by no means the only application. Membranes are also used in reverse osmosis, electrophoresis, dialysis, electrodialysis, gas separation, and immobilization and transfer of substances. Microfiltration is the regime with pores between about one-tenth of a micron and 10 microns. The most important pore size is .2 micron because this is the pore size that gives the highest flow rates and throughputs consistent with the retention of the approximate .3 micron Pseudomonas diminutia bacteria which is the criterion for a pore size rating equivalent to sterilization. Today commercially acceptable mi-crofiltration membranes are skinless and macrovoid-free and have a narrow pore size distribution which maximizes their efficiency at removing bacteria, and other particulate matter of equivalent size, from fluids.

Other uses for microfiltration membranes are now found more and more in the biotechnology area. Polymeric membranes are there employed, for example, to hold certain substances such as antibodies, antigens or other proteins while blood or other body fluids are passed through the membrane.

Over the years, many different polymers have been investigated as possible membrane media in a number of different applications. By the late 1970’s, the list included the following, without any attempt to be exhaustive:

Polymer

Application

Cellulose acetate and nitrate including mixtures

Electrophoresis Microfiltration Ultrafiltration Reverse Osmosis Gas Separation

Cellulose triacetate

Microfiltration Ultrafiltration

*1303 Polymer Application

Reverse Osmosis

Cellulose acetate/triacetate blends Reverse Osmosis

Polyacrylonitrile Ultrafiltration

Polyacrylonitrile-polyvinyl-chloride copolymer Mierofiltration

Polyamide (incl. various nylons) Mierofiltration Ultrafiltration Reverse Osmosis Immobilizing Medium

Polyaryl Sulfone Ultrafiltration

Polycarbonate Mierofiltration Reverse Osmosis Electrophoresis

Polyester Mierofiltration

Polyether Sulfone Ultrafiltration

Polyimide Ultrafiltration Reverse Osmosis Mierofiltration

Polypropylene

Polysulfone Mierofiltration Ultrafiltration

Polytetrafluoroethylene (PTFE) Mierofiltration

Polyvinylchloride Mierofiltration

Polyvinylidenefluoride (PVFD) Mierofiltration Ultrafiltration

Dr. Resting Direct Testimony at 7.

By 1978, many methods had been investigated for making the polymers mentioned above, and many other polymers not here mentioned in porous membranes. They included: casting membranes from a melt of the polymer; casting from a polymer solution into an evaporative atmosphere; casting from a polymer solution into a nonsol-vent liquid; stretching semi-crystalline films; thermal gelling by decreasing the temperature of the polymer solution; inducing porosity by irradiation of polyester and/or polycarbonate films; binding the polymer into a thin sheet structure by sin-tering.

In 1978, the leading manufacturers of mierofiltration media were Pall with its fibrous potassium titanate product, and Milli-pore with its membrane made of a mixture of cellulose nitrate and cellulose acetate.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Amgen, Inc. v. Hoechst Marion Roussel, Inc.
126 F. Supp. 2d 69 (D. Massachusetts, 2001)
Storer v. Hayes Microcomputer Products, Inc.
960 F. Supp. 498 (D. Massachusetts, 1997)
Pall Corp. v. Fisher Scientific Co.
962 F. Supp. 210 (D. Massachusetts, 1997)
Micron Separations, Inc. v. Pall Corporation
47 F.3d 1180 (Federal Circuit, 1995)
Avco Corp. v. PPG Industries, Inc.
867 F. Supp. 84 (D. Massachusetts, 1994)
Candela Laser Corp. v. Cynosure, Inc.
862 F. Supp. 632 (D. Massachusetts, 1994)

Cite This Page — Counsel Stack

Bluebook (online)
792 F. Supp. 1298, 1992 U.S. Dist. LEXIS 5883, 1992 WL 86686, Counsel Stack Legal Research, https://law.counselstack.com/opinion/pall-corp-v-micron-separations-inc-mad-1992.