§ 51:912.25 — Installation standards for used manufactured homes in hurricane zones
Louisiana § 51:912.25
JurisdictionLouisiana
Title 51Trade and Commerce
This text of Louisiana § 51:912.25 (Installation standards for used manufactured homes in hurricane zones) is published on Counsel Stack Legal Research, covering Louisiana primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.
Bluebook
La. Stat. Ann. § 51:912.25 (2026).
Text
§912.25. Installation standards for used manufactured homes in hurricane zones When the manufacturer's printed setup requirements are not available for the applicable wind zone, the following guidelines are to be used:
(1)All anchors shall be listed for four thousand seven hundred twenty-five pounds
ultimate load.
(2)Longitudinal ties only are required at each end of each unit. The minimum
number of ties at a minimum angle of forty-five degrees from vertical is three each for Zone
II and four each for Zone III.
(3)All designated tie points on the perimeter side walls shall be equipped with
vertical and diagonal ties with stabilizer devices. When tie points are not designated on the
side walls, diagonal ties with stabilizer devices shall be spaced a maximum of ten feet for
Zone I, eight
Free access — add to your briefcase to read the full text and ask questions with AI
Legislative History
Acts 1997, No. 970, §1; Acts 2000, 1st Ex. Sess., No. 92, §1; Acts 2001, No. 718,
§2; Acts 2007, No. 441, §1; Acts 2008, No. 217, §1; Acts 2017, No. 221, §1.
Nearby Sections
15
§ 51:912.1
§ 51:912.1§ 51:912.10
Exclusiveness§ 51:912.2
Short title§ 51:912.21
Definitions§ 51:912.23
Foundations and piers§ 51:912.26
Local installation standards preempted§ 51:912.28
Violations; penalties§ 51:912.3
Definitions§ 51:912.30
Mobile homes not coveredCite This Page — Counsel Stack
Bluebook (online)
Louisiana § 51:912.25, Counsel Stack Legal Research, https://law.counselstack.com/statute/la/51%3A912.25.