Text
The following specifications are standards set for used manufactured homes when manufacturer's installation instructions and specifications are not available:
(1)Anchors:
(a)All auger anchors shall be a minimum of thirty inches in height.
(b)All anchors shall be tested to an ultimate load of four thousand seven hundred twenty-five pounds.
(2)Frame ties:
(a)Used units where the manufacturer's specifications are not available shall be anchored every ten feet in Zone I, eight feet in Zone II, and six feet in Zone III, with anchors placed within two feet of each end.
(b)Frame ties shall make at least one complete wrap around the chassis or frame and shall be looped from the top of the I-beam to the anchor. However, some frame tie straps may have to extend from the bottom of the I-beam or
Free access — add to your briefcase to read the full text and ask questions with AI
Legislative History
Acts 1997, No. 970, §1; Acts 2000, 1st Ex. Sess., No. 92, §1; Acts 2001, No. 718, §2; Acts 2003, No. 661, §1; Acts 2008, No. 217, §1.
Nearby Sections
15
§ 51:912.1
§ 51:912.1§ 51:912.10
Exclusiveness§ 51:912.2
Short title§ 51:912.21
Definitions§ 51:912.23
Foundations and piers§ 51:912.26
Local installation standards preempted§ 51:912.28
Violations; penalties§ 51:912.3
Definitions§ 51:912.30
Mobile homes not coveredCite This Page — Counsel Stack
Bluebook (online)
Louisiana § 51:912.24, Counsel Stack Legal Research, https://law.counselstack.com/statute/la/51%3A912.24.