§ 44-2503 — REHABILITATION REQUIREMENTS

Idaho·Title 44 LABOR·Ch. 25 MOBILE HOME REHABILITATION

The mobile home shall meet the following rehabilitation requirements:

(1)A smoke detector (which may be a single station alarm device) shall be installed on any wall in a hallway or space communicating with each bedroom area and the living area on the living area side and, when located in a hallway, the detector shall be between the return air intake and the living area. Each smoke detector shall be installed in accordance with its listing and the top of the detector shall be located on a wall four (4) inches to twelve (12) inches below the ceiling. The detector may be battery-powered or may be connected to an electrical outlet box by a permanent wiring method into a general electrical branch circuit, without any switch between the over current protection device protecting the branch circ