Morris & Dickson Co. v. Jones Brothers Co., Inc.

691 So. 2d 882, 1997 WL 176460
CourtLouisiana Court of Appeal
DecidedApril 11, 1997
Docket29379-CA
StatusPublished
Cited by13 cases

This text of 691 So. 2d 882 (Morris & Dickson Co. v. Jones Brothers Co., Inc.) is published on Counsel Stack Legal Research, covering Louisiana Court of Appeal primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Morris & Dickson Co. v. Jones Brothers Co., Inc., 691 So. 2d 882, 1997 WL 176460 (La. Ct. App. 1997).

Opinion

691 So.2d 882 (1997)

MORRIS & DICKSON COMPANY, INC., Plaintiff-Appellee,
v.
JONES BROTHERS COMPANY, INC. and Commercial Union Insurance Company, Defendants-Appellants.

No. 29379-CA.

Court of Appeal of Louisiana, Second Circuit.

April 11, 1997.

*884 Simon, Peragine, Smith & Redfearn by Denise C. Puente, Daniel J. Caruso, and J. Thomas Hamrick, Jr., for Defendants-Appellants.

Taylor, Porter, Brooks & Phillips by Tom F. Phillips, for Plaintiff-Appellee.

Before NORRIS, HIGHTOWER and CARAWAY, JJ.

CARAWAY, Judge.

Conceding in this appeal the issue of its liability for a leaking underground gasoline storage tank, defendant, Jones Brothers Company, Inc. ("Jones"), appeals a jury verdict in favor of the plaintiff, Morris & Dickson Company, Ltd. ("M & D"), rearguing primarily that plaintiff's claims have prescribed. Additionally, Jones seeks review of the award for damages and interest and disputes the plaintiff's claim for attorney fees pursuant to the "Citizen Suits" provisions of La.R.S. 30:2026 of the Department of Environmental Quality Act, La.R.S. 30:2001 et seq. For the reasons stated hereinbelow, we affirm in part and reverse in part the rulings below and render judgment accordingly.

Facts

The Morris & Dickson Company, Ltd. is a wholesale distributor of pharmaceutical products located in Shreveport, Louisiana. In 1984, the company moved from downtown Shreveport to a newly constructed location south of town. M & D, the owner of the new premises, acted as its own general contractor in building the new facility, obtaining a building permit and contracting with other contractors to perform the various aspects of the job.

M & D wanted to provide a gasoline fueling facility for its fleet of delivery trucks. Toward this end, M & D sought a proposal from Jones to furnish and install two underground storage tanks (hereinafter "UST") with appurtenances that would allow M & D to fuel the delivery trucks. A proposal was submitted by Jones and accepted by M & D with certain modifications. These modifications addressed, among other things, the digging of the sites for the tanks by another contractor selected by M & D. According to testimony by M & D's president, Skipper Dickson, Jones was to provide its knowledge and expertise to M & D for the design, safety features, permits and the regulation compliance for the tank facility, and was to furnish the gasoline system and supervise its installation. The final invoices and other pertinent documents in the record indicate that total charge for goods and services supplied by Jones to M & D was $10,492. The sales price of the tanks and appurtenances was $5,806, indicating that the services provided by Jones were $4,686, or roughly 45% of the total invoice.

The two tanks, one with 4000 gallon capacity and the other with 6000 gallon capacity, were installed in 1984. The tanks were shaped in the form of large, horizontal cylinders with flat, vertical ends. As agreed, M & D contracted some of the excavation and installation work itself, with Jones overseeing all of the work and performing other installation *885 aspects of the job, which was performed from late February until April.

In early 1987, M & D realized that problems it had recently experienced with its fleet of trucks indicated that there was water in the gas coming from their storage tanks. M & D contacted Jones in early February regarding the problem. An employee from Jones discovered 5 ½ inches of water accumulated in the 4000 gallon tank. The water was pumped out of the tank by Jones. Problems with the water continued. The same problem occurred in subsequent months into 1988. The source of the water was unknown and according to M & D, Jones came on a regular basis to fix the problem and kept attempting to find the source of the problem. Eventually, in December of 1988, a leakage test known in the industry as a petrotite test was attempted on the 4000 gallon tank. The test was aborted, however, when it was ascertained that the tank or the system could not hold the requisite test pressure, which indicated a substantial leak in the tank or appurtenances.

In February, 1989, M & D and Jones decided to jointly dig the 4000 gallon tank out of the ground. Present at the time of the tank's removal was an inspector from the Louisiana Department of Environmental Quality ("DEQ"). A ½-inch hole was discovered in an area of corrosion near the top of one of the ends of the tank. It was also found that there had been groundwater contamination which would require remediation. On March 16, 1989, the DEQ issued an order to M & D to begin steps to clean up the site.

The hole in the tank was apparently caused by corrosion. The question was why the corrosion occurred so rapidly, perforating the tank in three years, when the life expectancy of such a tank is usually 20 to 30 years, but a very minimum of 10 years. Evidence presented at trial questioned whether the cause of the hole in the tank was due to either the failure to install anodes for "cathodic" protection[1] against corrosion, installation of inadequate anodes, the failure to seal the tank with a mastic substance such as asphalt, mechanical damage to the tank, highly corrosive soil, or some, none, or all of the above.

Mr. Kevin Garrity, an engineer testifying for M & D as an expert in corrosion of underground tanks, viewed the tank in 1993, some 4 years after it had been excavated from the ground, and after it had been cleaned up and transformed into an aboveground tank. He testified that there was no evidence of the protective coating present on the tank that is typically applied to prevent corrosion in underground tanks. He also testified that he did not see evidence of a cad-weld on the outside of the tank. Although he could not pinpoint the exact cause for the problem and expressed surprise at the extent of the corrosion arising in only three years of underground use, he concluded that the hole was caused either by the absence of cathodization or the improper installation of anodes coupled with mechanical damage to the tank at the place where the hole developed.

Testimony also showed that the soil at the site was highly corrosive. With such soil, M & D argued that the installation of the 17 pound anodes used, coupled with other circumstances, would have been insufficient to provide cathodic protection against corrosion.

Jones contends that it properly installed magnesium anodes to the tanks to provide the requisite cathodic protection. It presented the testimony of William "Bill" Jones, Jr., vice-president, and John Hodges, an employee of 27 years, that they together installed the anodes on the tanks using a cad-weld. Bill Jones also testified that the tanks had a black asphalt mastic coating. Hodges, now retired, corroborated Jones' testimony describing in detail the removal of the mastic coating on the tank to perform the cad-weld. Additionally, Daryl Guyton, the salesman for Jones who negotiated the deal with M & D, testified that M & D's Mark Dickson wanted four magnesium anodes for cathodic protection, but did not specify the size. Guyton *886 discussed the proper size with a Dr. Greco of F.W. Corrosion Company where later Jones purchased the anodes.

Following removal of the tank and the March 16, 1989 order from DEQ, M & D retained Southern Services to propose to the DEQ a plan of remediation.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Seth H. Schaumburg Versus Parish of Jefferson
Louisiana Court of Appeal, 2020
Daigle v. Cimarex Energy Co.
333 F. Supp. 3d 604 (W.D. Louisiana, 2018)
Hendrick v. Patterson
109 So. 3d 475 (Louisiana Court of Appeal, 2013)
Youngblood v. Southern Air, Inc.
58 So. 3d 1020 (Louisiana Court of Appeal, 2011)
Hollenshead Oil & Gas, LLC v. Gemini Explorations, Inc.
44 So. 3d 809 (Louisiana Court of Appeal, 2010)
Grefer v. Alpha Technical
901 So. 2d 1117 (Louisiana Court of Appeal, 2005)
La. Dotd v. Kansas City Southern Rwy. Co.
846 So. 2d 734 (Supreme Court of Louisiana, 2003)
Gunn v. Robertson
836 So. 2d 643 (Louisiana Court of Appeal, 2002)
Nicholas v. Allstate Ins. Co.
739 So. 2d 830 (Louisiana Court of Appeal, 1999)
Grocery Supply v. Winterton Food Stores
722 So. 2d 94 (Louisiana Court of Appeal, 1998)
Graf v. Jim Walter Homes, Inc.
713 So. 2d 682 (Louisiana Court of Appeal, 1998)

Cite This Page — Counsel Stack

Bluebook (online)
691 So. 2d 882, 1997 WL 176460, Counsel Stack Legal Research, https://law.counselstack.com/opinion/morris-dickson-co-v-jones-brothers-co-inc-lactapp-1997.