§ 50-74-218 — Safe Working Pressure
50-74-218 . Safe working pressure.
(1)If a boiler is constructed with lap horizontal seams on the boiler, dome, or drum, a factor of 4 1/2 must be used in determining the safe working pressure allowed on the boiler.
(2)If a boiler is constructed with butt strap horizontal seams, a factor of four may be used in determining the safe working pressure.
(3)If a boiler is a historical boiler, as defined by the department by rule, on stayed sections, a safety factor of four must be used in determining the safe working pressure.
(4)If a boiler rests on a side wall on lugs, is hung by I-beams, or is in any way set up so that the weight of the boiler is pulling against the horizontal seam of rivets, a factor of five must be used in determining the safe working pressure.
(5)If the horizontal lap