Romero v. ITW Food Equipment Group, LLC

987 F. Supp. 2d 93, 92 Fed. R. Serv. 1017, 2013 WL 5817670, 2013 U.S. Dist. LEXIS 155333
District Court, District of Columbia·Decided October 30, 2013·No. Civil Action No. 2011-1799·Published·Cited by 5 cases

Opinion

ORDER AND MEMORANDUM OPINION ON CROSS-MOTIONS FOR PARTIAL SUMMARY JUDGMENT, DEFENDANT’S MOTION TO EXCLUDE EXPERT TESTIMONY, AND DEFENDANT’S MOTION FOR SUMMARY JUDGMENT

BARBARA J. ROTHSTEIN, UNITED STATES DISTRICT JUDGE

Plaintiff Waldimir Romero suffered severe injuries when his right hand became caught in the meat grinder he was operating in the course of his employment. He brought this strict product liability action against the manufacturer of the meat grinder, Defendant ITW Food Equipment Group, LLC, asserting design and warning defect claims. Now before the Court are (1) cross-motions for partial summary judgment on the defense of assumption of the risk, (2) Defendant’s motion to exclude the testimony of Plaintiffs expert, Steven Kane, and (3) Defendant’s motion for summary judgment on the merits. The motions are GRANTED in part and DENIED in part with the following result: Plaintiffs expert testimony is admissible only as to the warning defect claim and that claim alone may proceed to trial. The Court’s reasons are set forth below.

I. BACKGROUND

The Hobart Model 4046, pictured below, is a heavy-duty commercial meat grinder used by grocers and other high-volume meat processing businesses. Model 4046 Specifications Sheet, Dkt. No. 24-2, at 1. When the Model 4046 is used as designed, pieces of cut meat are placed on the feed pan and slid under the guard over the opening to the feed cylinder, wherein the meat drops until it encounters the “worm,” an oversize screw that turns at 215 revolutions per minute. Id. The meat is pushed by the worm towards a rotating knife, which shears off pieces of meat and forces them through- a plate, producing ground meat. The Model 4046 can process up to 60 pounds of beef per minute. Id.

*98 [[Image here]]

The Model 4046 is equipped with a safety system to prevent operation without the guard in place. The feed pan, to which the guard is permanently attached, sits atop an interlock plunger that must be depressed in order for the motor to run. Model 4046 Instruction Manual, Dkt. No. 24-5, at 5. If the feed pan is removed, then the plunger is released and the machine is inoperable; if the feed pan is in place, then the plunger is depressed, the machine operates normally, and the guard prevents the operator’s hand from making contact with the worm. Id.

Defendant’s business records indicate that after November 1962, one warning label was to affixed “above Push Buttons and one in same location on opposite side of Housing” on each Model 4046. Materials List, Dkt. No. 24-3, at 335. The text of the label is printed below:

WARNING
DO NOT OPERATE THIS MACHINE WITHOUT THE SAFETY DEVICES PROVIDED BY HOBART:
1. GUARD OVER CYLINDER OPENING.
2. ELECTRICAL INTERLOCK UNDER FEED PAN.

Affidavit of William Schlieper, Dkt. No. 24-3, ¶¶ 3-4. Although the Model 4046 here at issue left Defendant’s control in 1967, Deposition of William Schlieper, Dkt. No. 23-6, at 80, the parties dispute whether it was in fact shipped with the warning label above, Plaintiffs CounterStatement of Material Facts, Dkt. No. 27-3, at 3 ¶ 14. No warning label was on the machine at the time of the accident in 2009. Id.

Plaintiff, who is originally from El Salvador, began working for Moby Dick’s House of Kabob in Washington, D.C. in late 2008 or early 2009. Deposition of Waldimir Romero (“Romero Depo”), Dkt. No. 23-5, *99 at 8-9. Plaintiff used a Model 4046 to grind chicken and onions. Id. at 24r-25. At his deposition, Plaintiff testified that he was not trained in the use of the Model 4046, was not given an instruction manual, and never saw any warnings on the machine or posted to the wall. Id. at 82-34. Instead, Plaintiff learned how to operate the Model 4046 by observing a co-worker. Id. at 33. Plaintiff observed the co-worker would remove the feed tray — to which the guard was attached — when grinding chicken because, Plaintiff surmised, the grease from the chicken made use of the feed tray difficult and time-consuming. Id. at 46-47, 53-55. Plaintiff therefore followed suit. Id. at 55. In order to defeat the interlock system, Plaintiff would set a bowl of chicken atop the plunger; he would then grab pieces of the chicken and throw them into the exposed feed cylinder. Id. at 56-58. Plaintiff testified that although he appreciated the danger of placing his hand inside the cylinder, id. at 58-59, he did not understand the purpose of the guard: “I didn’t know that it was specifically to protect anything. I thought it was to maybe put something on top.” Id. at 51.

On August 13, 2009, Plaintiff was standing on a step and using the unguarded Model 4046 to grind chicken. Id. at 62. Plaintiff testified that at some point his right leg suddenly bent forward, his right foot slipped off the step, and he fell forward towards the machine. Id. at 63- 64. His right arm, which was slippery from the fat and grease of the chicken, went into the feed cylinder and his hand was pulled into the worm. Id. at 64. Plaintiff suffered severe injuries to his right hand, which required amputation. Id. at 83-84.

In September 2011 Plaintiff brought this action in the Superior Court of the District of Columbia; soon thereafter Defendant removed the case to federal court. Notice of Removal, Dkt. No. 1. Plaintiff asserts strict product liability, negligence, and breach of warranty claims arising from alleged design and warning defects in the Model 4046. Complaint, Dkt. No. 1, at ¶¶ 14-40. Plaintiff claims the Model 4046 is defective in design because the guard is too easily removable, the interlock is too easily defeated, and the diameter of the feed cylinder is too large; Plaintiff also disputes whether the particular Model 4046 at issue was shipped with warning labels but argues that even if it were, the labels were inconspicuously located, insecurely attached, and lacking in size and content. Plaintiffs Opposition to Defendant’s Motion for Summary Judgment (“Pi’s Opp. to MSJ”), Dkt. No. 27-2, at 14, 29-30. Plaintiff relies principally upon an opinion prepared by his engineering expert, Steven Kane, in order to support his claims. See Opinion of Steven Kane (“Kane Op.”), Dkt. No. 28-4.

In October 2012, following unsuccessful efforts at mediation, the parties filed the three motions now before the Court. First, the parties cross-move for partial summary judgment on the defense of assumption ' of the risk. See Plaintiffs Motion for Partial Summary Judgment Regarding Affirmative Defense of Assumption of Risk, Dkt. No. 21; Defendant’s Cross Motion for Summary Judgment (“Defs Cross Mot.”), Dkt. No. 24. Second, • Defendant moves to exclude the testimony of Steven Kane on the ground that it falls below the standard of reliability set forth in Daubert v. Merrell Dow Pharmaceuticals, Inc., 509 U.S. 579, 113 S.Ct. 2786, 125 L.Ed.2d 469 (1993). See

Free access — add to your briefcase to read the full text and ask questions with AI

Romero v. ITW Food Equipment Group, LLC, 987 F. Supp. 2d 93, 92 Fed. R. Serv. 1017, 2013 WL 5817670, 2013 U.S. Dist. LEXIS 155333 (D.D.C. 2013).

987 F. Supp. 2d 93 (Romero v. ITW Food Equipment Group, LLC) — published by Counsel Stack Legal Research, free access to 12M+ legal documents.