Karl Frederick Schultz v. State

Procedural entryThis page is a short order in Karl Frederick Schultz v. State. Read the opinion of the Court — 2014 Tex. App. LEXIS 12566
Court of Appeals of Texas·Decided November 20, 2014·No. 01-13-00505-CR·Published

Opinion

Opinion issued November 20, 2014

In The

Court of Appeals

For The

First District of Texas

subject to his right to appeal the ruling on the motion to suppress. The trial court found appellant guilty and assessed punishment at confinement for one year. The trial court then suspended the sentence and placed Appellant on community supervision. On appeal, Appellant argues in three issues that (1) the trial court abused its discretion by excluding certain evidence from the suppression hearing, (2) the breath test results should have been suppressed because they were obtained in violation of the law, and (3) the breath test results should have been suppressed because they were not reliable.

We affirm.

Background

Appellant was arrested in the early morning hours of January 7, 2012 for driving while intoxicated. Appellant stipulated at the suppression hearing that reasonable suspicion existed for a detention, that probable cause justified his arrest, and that the required statutory warnings were properly given to him. The arresting officers took Appellant to a nearby gas station. Parked at the gas station was a Houston Police Department Breath Alcohol Testing van. Appellant agreed to give a breath test.

Officer D. Ciers testified at the suppression hearing. He testified that he brought appellant into the van and closed the door. It was a cool morning—about 72 degrees Fahrenheit inside the van—and the air conditioner was not running in

the van. Officer Ciers observed Appellant for a 15-minute period and then conducted the breath test using a machine mounted inside the van called the Intoxilyzer 5000.

Ronald Oliver, a technical supervisor for the Texas Department of Public Safety, also testified at the suppression hearing. Part of Oliver’s responsibilities as a technical supervisor was to regularly inspect and calibrate the breath test machines. Oliver testified that the breath test machine used on Appellant was inspected about one week before Appellant’s test. He also testified that Appellant’s test was the first one after the inspection. When questioned about whether the inspections on the machines were valid when the machines were used in a mobile van, Oliver testified,

A testing site is a testing site. Whether it has wheels or not doesn’t make any difference. If the testing site is appropriate, then you can get good, valid alcohol results from that instrument. If it’s in a bad location, whether it have wheels or not have wheels; that we have testing sites in jails that overheat and there are times when we can’t run tests, then that physical location is it’s just too hot or too cold.

Oliver also testified about the approval of the Houston Police Department’s breath testing program by the Texas Department of Public Safety’s scientific director. Specifically, Oliver testified,

Q. And is [the Intoxilyzer 5000 that was used on Appellant]

certified by the scientific director of the Texas Department of Public Safety?

A. Yes.

Q. And was it certified on the date of January 7th, 2012?

A. That is correct.

Q. And is that instrument used as a part of the breath test program?

A. That is correct.

Q. Are you responsible for the maintenance of that instrument?

A. I was, yes.

Finally, Oliver testified at trial about the Intoxilyzer 5000’s many failsafes for inaccurate breath tests. The machine tests for the presence of alcohol, specifically ethanol. Ethanol absorbs a specific wavelength of infrared light. When that wavelength of light is passed through the air chamber, less of the light will come out the other side of the chamber due to its absorption by the ethanol. A measure of the decrease in the amount of the infrared light establishes the amount of ethanol present in the sample.

Other known chemicals can also absorb infrared light at the same wavelength. These are called interferents and can potentially cause a false identification of ethanol. To account for this, the machine also tests for five known interferents, such as acetone. If any interferents are detected, the machine subtracts the amount of interferents detected from the total amount detected for the test wavelength.

Every time the machine is run, it performs a test of its internal components to ensure that the circuitry is functioning properly. If it is not functioning properly, the test ends and the report explains an error occurred.

Next, it purges the system of the air in it at the time, drawing in air from its current environment. The machine then tests that air sample. The test subject then breathes into a tube connected to the machine. The machine tests that breath sample as well. It then performs another test from the current environment. After that, the machine then tests what is known as a reference sample. The reference sample is designed to produce a result for a specific volume of alcohol. The test subject then breathes again in the tube, and the machine tests that sample as well. Another sample of the air in the current environment is tested. Finally, the machine draws another sample in from the environment and tests it again.

After the tests are complete, the machine prints out a report showing the results for each test. If any errors occur during the testing, the report explains an error occurred and does not include the testing results. Potential errors include improperly functioning circuitry, overheating, being overly cold, interferents being detected in the ambient air samples, and the two breath samples from the test subject being too far apart.

In the present case, the report did not identify any errors. It identified the alcohol concentration for the first air sample at 0.000. It identified the alcohol

concentration for Appellant’s first breath sample at 0.158.2 It identified the alcohol concentration for the second air sample at 0.000. The reference sample was predicted to identify an alcohol concentration of 0.080. The machine identified the alcohol concentration for the reference sample at 0.077. It identified the alcohol concentration for the third air sample at 0.000. It identified the alcohol concentration for Appellant’s second breath sample at 0.168. Finally, it identified the alcohol concentration for the fourth air sample at 0.000.

Appellant presented the expert testimony of Raymond McMains. McMains had been a technical supervisor for the Texas Department of Public Safety for 17 years. McMains testified that he was aware of some tests where ethanol and acetone were tested in a sample together. “And a few times it did not detect that. And in one case it didn’t subtract it because they used a .08 solution and it showed up a .09.” McMains also testified that, based on his study of breath tests conducted throughout the state from 2007 to 2011, “the Houston [breath alcohol testing] vans were nine times more likely to detect an interferent than a nonmobile Intoxilyzer site.”

After all the witnesses had testified, Appellant offered into evidence a marketing brochure from the company that makes the Intoxilyzer 5000. The

2 Breath tests in Texas are a measurement of grams of alcohol per 210 liters of breath. TEX. PENAL CODE ANN. § 49.01(1)(A) (Vernon 2011).

brochure was for a machine called the Intoxilyzer 8000. There was no sponsoring witness.

Admission of Evidence

Free access — add to your briefcase to read the full text and ask questions with AI

Karl Frederick Schultz v. State, (Tex. Ct. App. 2014).

Karl Frederick Schultz v. State (Karl Frederick Schultz v. State) — published by Counsel Stack Legal Research, free access to 12M+ legal documents.

Related

TGS-NOPEC GEOPHYSICAL CO. v. Combs
340 S.W.3d 432 (Texas Supreme Court, 2011)
Pham v. State
175 S.W.3d 767 (Court of Criminal Appeals of Texas, 2005)
Valtierra v. State
310 S.W.3d 442 (Court of Criminal Appeals of Texas, 2010)
Reynolds v. State
204 S.W.3d 386 (Court of Criminal Appeals of Texas, 2006)
Hooper v. State
214 S.W.3d 9 (Court of Criminal Appeals of Texas, 2007)
Delao v. State
235 S.W.3d 235 (Court of Criminal Appeals of Texas, 2007)
King v. State
953 S.W.2d 266 (Court of Criminal Appeals of Texas, 1997)
Granados v. State
85 S.W.3d 217 (Court of Criminal Appeals of Texas, 2002)
Garza v. State
126 S.W.3d 79 (Court of Criminal Appeals of Texas, 2004)
Ray v. State
178 S.W.3d 833 (Court of Criminal Appeals of Texas, 2005)
Atkinson v. State
923 S.W.2d 21 (Court of Criminal Appeals of Texas, 1996)
Motilla v. State
78 S.W.3d 352 (Court of Criminal Appeals of Texas, 2002)
Maxwell v. State
73 S.W.3d 278 (Court of Criminal Appeals of Texas, 2002)
Robinson v. State
236 S.W.3d 260 (Court of Appeals of Texas, 2007)
Ford v. State
305 S.W.3d 530 (Court of Criminal Appeals of Texas, 2009)
State v. Ross
32 S.W.3d 853 (Court of Criminal Appeals of Texas, 2000)
Cantu v. State
817 S.W.2d 74 (Court of Criminal Appeals of Texas, 1991)
Kelly v. State
824 S.W.2d 568 (Court of Criminal Appeals of Texas, 1992)
Watson, Crystal Michelle
369 S.W.3d 865 (Court of Criminal Appeals of Texas, 2012)
Gonzales v. State
369 S.W.3d 851 (Court of Criminal Appeals of Texas, 2012)