Farm Credit Bank v. United States Mineral Products Co.

864 F. Supp. 643, 1994 WL 568462
CourtDistrict Court, W.D. Kentucky
DecidedAugust 26, 1994
DocketCiv. A. 91-0126-L(CS)
StatusPublished
Cited by12 cases

This text of 864 F. Supp. 643 (Farm Credit Bank v. United States Mineral Products Co.) is published on Counsel Stack Legal Research, covering District Court, W.D. Kentucky primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Farm Credit Bank v. United States Mineral Products Co., 864 F. Supp. 643, 1994 WL 568462 (W.D. Ky. 1994).

Opinion

MEMORANDUM OPINION

SIMPSON, District Judge.

This matter stands submitted on two motions for summary judgment by the defendant, United States Mineral Products (hereinafter “USMP”). USMP claims that plaintiff, Farm Credit Bank (hereinafter “FCB”), is barred from bringing this action due to its failure to comply with the relevant statute of limitations. USMP alternatively asserts in a second summary judgment motion that FCB has improperly calculated its damages.

[Material at this point was deleted by Judge Simpson for purposes of publication.]

I

The Farm Credit Bank Budding is located at 201 West Main Street, Louisville, Kentucky, and was constructed in the late 1960s and early 1970s. During construction, fireproofing was sprayed onto the underside of the concrete floor slabs, metal deck, and structural steel. The fireproofing, which was manufactured by USMP, contained anywhere between 20% to 30% chrysotile asbestos. According to EPA definitions, the fireproofing was “friable.” This means that it was capable of being reduced to a fine powder by hand pressure.

Title to the braiding was transferred several times during the early 1970s. FCB did not obtain title until sometime in 1975. It moved into the building on May 30, 1975. During the 1970s, the scientific community began to articulate concerns about health risks posed by asbestos. It was also during this time that the federal government began passing various regulations either limiting or restricting the use of asbestos products.

The question of whether asbestos was present in building products installed in the FCB building first arose in 1978. Ray Sanders, the braiding manager of FCB, asked Thomas Jones, one of the architects involved in the building’s design, whether the bundrag’s fireproofing was of an asbestos material. Mr. Jones responded on August 4, 1978, that it was his belief and the belief of those who applied the fireproofing that it did contain an asbestos fiber which was permissible at that time. However, he stated that this was just an assumption and that the material would have to be tested before that could be confirmed.

It was not until October 10, 1980 that Sanders again asked Jones to follow up on whether the fireproofing material did indeed contain asbestos. In the interim, James Willoughby, who had been hired as a maintenance employee at FCB, noticed that in some places the fireproofing had fallen off and landed on various ceiling tiles. In Sanders’ follow-up letter, he asked Jones to determine if the material contained an asbestos fiber that was “being regarded by some agencies as a long range health hazard.” Jones, pursuant to the request of Sanders, sought information from a sales manager of USMP about the asbestos content of its product. By letter dated November 24,1980, Jones responded to Sanders’ inquiry indicating that his research had led him to the conclusion that the product used was asbestos free. However, he stated that he wanted to make sure that the product used in FCB’s building was *645 the same product he found to be non-toxic. He concluded by adding that if he found out anything of further interest he would let FCB know.

This seemed to convince FCB that it had no cause for concern, and the issue of asbestos did not arise again until late 1984. Apparently Sanders again became concerned as to whether the fireproofing contained asbestos, and a sample of it was sent to Pittsburgh Testing Laboratory. In its report dated December 10, 1984, Pittsburgh Testing Laboratory revealed that the material tested positive for asbestos.

It is unclear when exactly Sanders learned of the Pittsburgh report. However, sometime in mid-1985 Sanders read a Governor’s Consumers Advisory Council report entitled Confronting the Problems of Asbestos in Kentucky: Findings with Recommendations for Action. One of the experts whose testimony was included in this report was that of David Banks. On September 25, 1985, Banks sent a letter to Sanders stating that he understood FCB might be seeking professional help concerning an asbestos related problem in its building. Shortly thereafter, FCB proceeded to hire Banks to conduct an asbestos survey of its building. The survey, which included bulk and air samples as well as a written report, was conducted and released on November 29, 1985. The report confirmed that asbestos-containing building materials, including fireproofing, were present in the building. However, the report also indicated that although asbestos-containing products were present, there was no detectable asbestos in the air. Nevertheless, the report made several recommendations including the following:

1. Now that friable asbestos-containing materials have been documented inside the building, occupants should be made aware of their presence and precautions they can take to avoid exposure to these materials. Legal counsel should be consulted to determine the best approach of informing persons involved. As a part of this notification, asbestos warning signs should be posted in areas where those materials may be encountered such as mechanical equipment rooms, penthouse, above suspended ceilings and on parking levels. Signs are important in warning persons not familiar with the building or this report who may come in contact with the asbestos. Such persons are maintenance and service personnel working for outside service companies, contractors, safety enforcement agencies, etc.
2. Until such time as asbestos in the building can be permanently abated, steps should be taken to protect occupants from exposure. These include continuous monitoring of these materials and cleanup followed by encapsulation of any damaged areas where friable material is dislodged or left exposed to the air or contact by persons. Maintenance staff are key to the success of these operations. They should receive special instruction covering what conditions to look for and steps to take in safely cleaning up any loose or damaged materials. Each instance should be reported and appropriate documentation filed in a permanent file....
4. Until permanent measures are taken to resolve possible exposure to asbestos, periodic testing of the air inside the building should be conducted using qualified consultants and laboratories. Although our testing indicated no problem at the time of testing, it should be remembered that testing was done at a time of very low activity within the building (a weekend). Conditions do change and when they do, the potential for changes in the airborne concentration of fibers exists. Periodic test data is also an important part of the permanent asbestos record____
7. A plan for dealing with asbestos-containing materials in the budding on a long term basis should be developed soon. Once the presence of asbestos has been established, it is important to take steps to prevent exposure by employees or the public, and it is important to document the steps taken. *646 Professional consultants should be engaged to help in developing the plan.
Options available for consideration include removal, encapsulation and enclosure. Discussions and comparisons of these options is beyond the scope of this report since costs and disruption to office operations vary from one to the other.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

CPC Livestock, LLC v. Fifth Third Bank, Inc.
495 B.R. 332 (W.D. Kentucky, 2013)
Electric Insurance v. Freudenberg-NOK, General Partnership
487 F. Supp. 2d 894 (W.D. Kentucky, 2007)
Son v. Coal Equity, Inc.
293 B.R. 392 (W.D. Kentucky, 2003)
Velsicol Chemical Corp. v. Winograd
956 S.W.2d 529 (Texas Supreme Court, 1997)
McKinney v. Fairchild International, Inc.
487 S.E.2d 913 (West Virginia Supreme Court, 1997)
Chase Manhattan Bank, N.A. v. T & N PLC
905 F. Supp. 107 (S.D. New York, 1995)
San Francisco Unified School District v. W.R. Grace & Company-Connecticut
37 Cal. App. 4th 1318 (California Court of Appeal, 1995)
NCR Corp. v. U.S. Mineral Products Co.
1995 Ohio 191 (Ohio Supreme Court, 1995)
NCR Corp. v. United States Mineral Products Co.
72 Ohio St. 3d 269 (Ohio Supreme Court, 1995)
White v. North Louisiana Legal Assistance Corp.
468 F. Supp. 1347 (W.D. Louisiana, 1979)

Cite This Page — Counsel Stack

Bluebook (online)
864 F. Supp. 643, 1994 WL 568462, Counsel Stack Legal Research, https://law.counselstack.com/opinion/farm-credit-bank-v-united-states-mineral-products-co-kywd-1994.