Estate of Charles D. v. Wright Hardware Co.

128 N.E.3d 485
Indiana Court of Appeals·Decided August 27, 2019·No. Court of Appeals Case No. 18A-CT-2527·Published·Cited by 2 cases

Opinion

Riley, Judge.

STATEMENT OF THE CASE

[1] Appellants-Plaintiffs, The Estate of Charles D. Benefiel, by and through its Co-Personal Representatives, Michael D. Benefiel and Andrea D. Kessner, and the Estate of Linda D. Benefiel, by and through its Co-Personal Representatives Michael D. Benefiel and Andrea D. Kessner (collectively, the Estate), appeal the verdict in favor of Appellee-Defendant, Wright Hardware Co., Inc. (Wright Hardware), in a negligence case arising out of a propane gas explosion wherein Charles and Linda Benefiel were killed.

*487[2] We reverse and remand for a new trial.

ISSUES

[3] The Estate raises three issues on appeal, which we consolidate and restate as: Whether the trial court abused its discretion in permitting a defense expert witness to read verbatim into evidence an opinion set forth in an email to the defense expert witness.

FACTS AND PROCEDURAL HISTORY

[4] This appeal follows a defense verdict in a negligence case arising out of a propane gas explosion that killed Charles and Linda Benefiel in their rural Clinton County residence. The Benefiel home was built in 1983 and, at the time of the explosion, the residence used propane gas service for heat and to fuel other gas appliances in their home. Beginning in 2000, the Benefiels became customers of Wright Hardware when Wright Hardware installed a 500-gallon liquid propane gas tank at the residence.

[5] On October 19, 2015, at 9:37 a.m., Wright Hardware employee Chuck Watkins received a call from the Benefiels, complaining they had no heat in the residence. William Taylor (Taylor) responded to the complaint and discovered the control board and gas valve were no longer functioning. He replaced both components. To complete the replacement, Taylor shut the gas off at the gas shut-off valve for the furnace, which terminated the gas service to the furnace only and left the gas on everywhere else in the house. He then disconnected the piping from the furnace. After reassembling the piping, Taylor used a manometer to test the flow pressure to the manifold to ensure the pressure was correct for the furnace. He tested the regulator on the new gas valve to check it was consistently producing the required pressure. In addition, he sniffed around the area and failed to detect any propane in the immediate vicinity. Finally, Taylor soap-tested the pipe fittings, but did not perform a leak test. Not finding any leaks, Taylor turned the gas on to cycle through the furnace a few times.

[6] On October 21, 2015, Wright Hardware delivered propane gas to the Benefiels' residence and filled the tank to eighty percent capacity. Two days later, on October 23, 2015, an explosion occurred which was followed by a fire, creating a debris field of 150 to 200 feet away from the residence. The home was substantially destroyed along with the surrounding buildings. It is not disputed by the parties that the explosion was caused by propane gas, which had been sold by Wright Hardware to the Benefiels, and which had leaked inside the residence.

[7] Following the explosion, various experts investigated the incident in an effort to determine the occurrence of the leak and the causation of the explosion and fire. The explosion's magnitude made it impossible to ascertain the source of the leak, the ignition incident, or actual cause of the explosion. Nevertheless, the experts agreed that the explosion had been caused by propane gas of undetermined origin, and although the source of the leak could not be isolated, the leak had originated inside the house.

[8] Propane gas is flammable and dangerous; it is heavier than air and tends to pool in low places when it is released. Unlike other gases, it builds up over time if there is no air to move it and reaches an explosive level when it finds an ignition source. Several sets of standards and codes govern propane gas systems. The National Fire Protection Association (NFPA) 58 instituted a set of standards dealing with liquid petroleum gas installations *488which apply to piping outside the house. The International Fuel Gas Code (IFGC), published by the International Code Council, applies to propane or natural gas piping inside the house. Although Indiana has largely adopted the 2012 edition of the IFGC, the legislature has incorporated significant revisions and added provisions. See I.C. § 22-13-2-2 ; 675 Ind. Admin. Code 25-3-1 et seq . To reduce the risk of a propane explosion, the codes require that certain tests, including pressure tests and leak tests, be performed under certain circumstances. Together, the pressure tests and leak test confirm whether the entire system is "gas tight," i.e ., not leaking. (Transcript Vol. III, p. 242). Section 4.6.6.3 of the IFGC, adopted in Indiana, provides that a leak test of the piping system shall be performed after a new installation or if there has been an "interruption of service." However, no statutory definition of what constitutes an interruption of service is included.

[9] On January 25, 2016, the Estate filed its Complaint for Damages sounding in negligence against Wright Hardware. On September 17, 2018, a five-day jury trial commenced. The Estate's theory of liability focused on Wright Hardware's failure to perform leak testing of the Benefiel home after Taylor replaced the control board and gas valve. According to the Estate, Taylor's work on the Benefiel's furnace by turning the gas shut-off valve constituted an interruption of service that required leak testing pursuant to the relevant provisions of the Indiana Fuel Gas Code (Ind. FGC). During the trial, several plaintiff and defense experts testified. The Estate's experts opined that Taylor needed to leak test the Benefiel gas system because shutting off the gas at the shut-off valve constituted an interruption of service. On the other hand, Wright Hardware's expert informed the jury that leak testing was not necessary because no interruption of service had occurred. In support of this opinion, Wright Hardware's expert, Todd Hetrick (Hetrick), had contacted the International Code Council (ICC), the drafters of the IFGC, and requested their interpretation of interruption of service, by posing an hypothetical fact pattern identical to this cause. More specifically, Hetrick questioned

[w]here the Code uses the term 'interruption of service ,' does this refer only to an interruption in fuel gas supply to the point of delivery (i.e., an outage of fuel gas supply from an onsite tank or utility to a customer's property), or does this term refer more broadly to also include a lack of fuel gas supply to a branch or isolated section of the piping system existing within a built structure, downstream of the point of delivery ? Please provide guidance to define the term 'interruption of service .'

(Appellant's App. Vol. II, p. 74).