Dean Hales v. Green Colonial, Inc., a Corporation v. Harold Munroe, Third Party

490 F.2d 1015
CourtCourt of Appeals for the Third Circuit
DecidedFebruary 6, 1974
Docket73-1122, 73-1136 and 73-1139
StatusPublished
Cited by54 cases

This text of 490 F.2d 1015 (Dean Hales v. Green Colonial, Inc., a Corporation v. Harold Munroe, Third Party) is published on Counsel Stack Legal Research, covering Court of Appeals for the Third Circuit primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Dean Hales v. Green Colonial, Inc., a Corporation v. Harold Munroe, Third Party, 490 F.2d 1015 (3d Cir. 1974).

Opinions

LAY, Circuit Judge.

This is an appeal from money damages awarded for the destruction of a building and its contents by a fire allegedly caused by a defective heater. The trial court submitted the cause to the jury on the theory of strict liability under Missouri law. The jury awarded plaintiffs $102,594.00. The trial court overruled defendants’ motion for a judgment notwithstanding the verdict and their alternate motion for a new trial. We affirm.

Plaintiffs, Dean Hales, Bernadine Hales and James Mogg, were the owners and operators of a Ben Franklin Store in Hamilton, Missouri. In June of 1970, they moved the location of their store to a remodeled building. To determine the heating needs of their new store they contacted Harold Munroe, a licensed plumber and heating installer, who along with a representative of Green Colonial, Inc., an Iowa supplier of heating equipment, visited the premises. Munroe determined that both a 300,000 BTU heating unit and a 150,000 BTU heating unit were necessary to sufficiently heat the store. Munroe ordered from Green Colonial two Peerless brand heaters, specifying that they burn LP gas (propane) since Hamilton had no natural gas supply. Green Colonial in turn placed the order for the two Peerless heaters with Iowa Plumbing Supply, Inc., a distributor in Des Moines, Iowa (IPS). Dover Corporation was the manufacturer of Peerless heater units.

[1017]*1017IPS furnished to Green Colonial one 150.000 BTU propane heater and one 300.000 BTU natural gas unit with a conversion kit so that it could be used with propane gas. Green Colonial sent these units on to Munroe. Both of the heaters were installed by Munroe and connected to a propane gas tank by the Solar Gas Company of Hamilton. In October of 1970 Munroe converted the 300.000 BTU natural gas heater by using a conversion kit sent to him from Dover.1 The conversion kit is manufactured by a different company but Dover supplies them to be used for converting their natural gas heaters. In making the conversion Munroe reduced all the orifices, reduced the elbow pipe and substituted an LP gas valve for the one used for natural gas. He likewise changed the blue tag which was on the natural gas heater to a red tag which designated a propane heater. The red tag along with the orifices, valve and elbow pipe constituted the packaged conversion kit sent by Dover to Munroe. Dover did not send any instructions with the kit. Munroe testified he had made conversions before and was familiar with the procedure. The heaters were operated for approximately a week at which time they were inspected by Munroe. He found the flame to be normal.

In early November the plaintiffs began noticing strange popping and exploding noises coming from the 300,000 BTU heater. On December 10, the gas company representative came and adjusted the gas pressure to 11 inches of water column, the specified setting required by Dover. According to Dover’s experts the reading was taken erroneously and was made at the wrong place. The noises continued and on December 18, a fire caused by the larger heater ignited the combustible contents of the store and destroyed the building.

Plaintiffs brought suit against Green Colonial, Dover and IPS. Dover sought indemnity against Harold Mun-roe, the installer. Green Colonial and IPS brought cross-claims for indemnity against Dover. The jury returned a verdict against the three defendants. Prior to the submission of the case to the jury, the trial court dismissed the claim against Munroe.2 The court has reserved its ruling on the cross-claims by Green Colonial and IPS against Dover.

On appeal several grounds of error are raised by the defendants. We find only two issues deserve extended consideration: (1) whether the evidence was sufficient to submit the defendants’ liability under the doctrine of strict liability; and (2) whether damages awarded for consequential loss are proper in Missouri under strict liability. We have reviewed the other grounds of error and find they facially lack merit and do not warrant discussion.3

In regard to the first issue the defendants contend that (a) there has been no showing of an unreasonably dangerous defect, (b) the product was substantially changed from the condition in which Dover originally sold it, and (c) the plaintiff was guilty of contributory fault.

THE DEFECTIVE HEATER

Plaintiffs’ evidence that the Peerless heater, as converted, was defective rests solely on the testimony of Alfred Ben-[1018]*1018berg, a consulting engineer and architect, registered in the State of Missouri. After examination of the Peerless unit he opined that the heater was defective for two reasons: (1) it did not have a flame tube which would ignite all the burners simultaneously, and (2) the air shutter bar was designed in such a manner as to cause delayed ignition regardless of how it was adjusted. He testified that these two defects caused the heater to backflash thereby igniting combustible goods on display in the store. Defendants attack this testimony as being speculative and without any scientific or engineering certainty. They couple this attack with the fact that their expert witnesses, also licensed engineers, suggest that the burner was operating without sufficient gas pressure and that this in reality caused the fire. They urge that the manual setting of the air adjustment bar by Mr. Mun-roe, the installer, along with the improper pressure set by the gas company caused a delayed ignition and the resulting fire. The defendants also offered testimony that the particular heater in question had been certified as being safe and properly designed by the American Gas Association, a trade organization for the natural gas industry.

Plaintiffs’ evidence as to causation causes this court, as it did the trial court, a good deal of difficulty. Mr. Benberg’s opinion that the air adjustment valve did “not provide sufficient air adjustment to be sure that you get an even distribution through the burners” is not amplified or explained. This theory was not developed in any detail during either the direct or cross examinations. As the defendants suggest Mr. Benberg’s explanation is confusing to say the least.4

Defendants’ engineer points out that LP gas requires 10% less air for combustion than natural gas. His testimony was that the adjustment of the air vent cannot in any way affect the velocity of the gas but simply affects the mixture of the air with the gas, thus determining whether there will be a rich or lean combustion. Plaintiffs urge on appeal that the fault with the air vent lies with the fact that the air adjustment bar is not designed to allow for individual adjustment to any one of the 18 burners. The record shows, however, that Mr. Benberg did not attribute the cause of the fire to the absence of individual adjustment. His testimony points up that the triangular flanges or fingers on the bar can be individually adjusted. Mr. Benberg’s complaint is that there is not an even distribution throughout all the burners. Without further explanation we find Mr. Benberg’s bare conclusion concerning the air bar insufficient to sustain the verdict.

However, notwithstanding this shortcoming, we find it a fair inference from his testimony that the basic heater lacked a flame tube in the back of the burners which would provide uniform ignition from the single pilot light. This is explained by Mr. Benberg as follows:

A.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Carlisto v. General Motors Corp.
870 S.W.2d 505 (Missouri Court of Appeals, 1994)
Interocean Ships, Inc. v. Samoa Gases
23 Am. Samoa 2d 76 (High Court of American Samoa, 1992)
National Union Fire Insurance v. Pratt & Whitney Canada, Inc.
815 P.2d 601 (Nevada Supreme Court, 1991)
G&M Farms v. Funk Irrigation Co.
808 P.2d 851 (Idaho Supreme Court, 1991)
Continental Insurance v. Page Engineering Co.
783 P.2d 641 (Wyoming Supreme Court, 1989)
C & K LORD, INC. v. Carter
536 A.2d 699 (Court of Special Appeals of Maryland, 1988)
GOLMEZ v. Clark Equipment Co.
743 S.W.2d 429 (Missouri Court of Appeals, 1987)
Anderson v. Dreis & Krump Manufacturing Corp.
739 P.2d 1177 (Court of Appeals of Washington, 1987)
United States v. Conservation Chemical Co.
661 F. Supp. 1416 (W.D. Missouri, 1987)
Zacher v. Budd Co.
396 N.W.2d 122 (South Dakota Supreme Court, 1986)
Alberg v. Hardin Marine Corp.
387 N.W.2d 779 (Court of Appeals of Iowa, 1986)
Roxalana Hills, Ltd. v. Masonite Corp.
627 F. Supp. 1194 (S.D. West Virginia, 1986)
Streich v. Hilton-Davis, Div. of Sterling Drug
692 P.2d 440 (Montana Supreme Court, 1984)
Gunderson v. Sani-Kem Corp.
674 S.W.2d 665 (Missouri Court of Appeals, 1984)
Anderson Banks v. Iron Hustler Corp.
475 A.2d 1243 (Court of Special Appeals of Maryland, 1984)
Lewis v. Envirotech Corp.
674 S.W.2d 105 (Missouri Court of Appeals, 1984)
Emerson G.M. Diesel, Inc. v. Alaskan Enterprise
732 F.2d 1468 (Ninth Circuit, 1984)
Jarrell v. Fort Worth Steel & Manufacturing Co.
666 S.W.2d 828 (Missouri Court of Appeals, 1984)
Duke v. Gulf & Western Manufacturing Co.
660 S.W.2d 404 (Missouri Court of Appeals, 1983)

Cite This Page — Counsel Stack

Bluebook (online)
490 F.2d 1015, Counsel Stack Legal Research, https://law.counselstack.com/opinion/dean-hales-v-green-colonial-inc-a-corporation-v-harold-munroe-third-ca3-1974.