§ 53.715 Maintenance, repair, and inspection programs.

(a)A program to control maintenance activities and monitor the performance or condition of SR and NSRSS SSCs must be developed, implemented, and maintained.
(b)Whenever a licensee determines through activities related to maintenance, repair, and inspection of SSCs, the activities under § 53.710, or otherwise that the performance or condition of an SR or NSRSS SSC does not demonstrate compliance with established special treatments or performance goals related to capabilities, availability, or reliability, the licensee must take appropriate corrective action.
(c)Performance and condition monitoring activities and associated goals and preventive maintenance activities must be evaluated at least every 24 months. The evaluations must t