(a)In all blasting operations, except as otherwise provided in this chapter, the maximum ground vibration at a dwelling, public building, school, church, or commercial or institutional building normally occupied adjacent to the blasting site must not exceed the limitations specified in the following graph shown in Figure A to limit peak particle velocity based upon the frequency of the blast vibration: Click here to view image.
(b)Unless a blaster uses a seismograph to monitor a blast to ensure compliance with Figure A, the operation shall comply with the scaled distance equations shown in the following Table 1. TABLE 1 SCALED DISTANCE EQUATIONS Distance from Blasting Site Scaled Distance Equation 0 to 300 ft (91.4 m) Standard Table of Distance 301 to 5000 ft (92 m to 1524 m) W (lbs) = (
Free access — add to your briefcase to read the full text and ask questions with AI
(a) In all blasting operations, except as otherwise provided in this chapter, the maximum ground vibration at a dwelling, public building, school, church, or commercial or institutional building normally occupied adjacent to the blasting site must not exceed the limitations specified in the following graph shown in Figure A to limit peak particle velocity based upon the frequency of the blast vibration: Click here to view image. (b) Unless a blaster uses a seismograph to monitor a blast to ensure compliance with Figure A, the operation shall comply with the scaled distance equations shown in the following Table 1. TABLE 1 SCALED DISTANCE EQUATIONS Distance from Blasting Site Scaled Distance Equation 0 to 300 ft (91.4 m) Standard Table of Distance 301 to 5000 ft (92 m to 1524 m) W (lbs) = (d (ft)/55) 2 or W (kg) = (d (m)/24.9) 2 5001 ft (1524 m) and beyond W (lbs) = (d (ft)/65) 2 or W (kg) = (d (m)/29.4) 2 Key: W = The maximum weight of explosives in pounds (or kilograms) that can be detonated per delay interval of 8 milliseconds or greater. d = The distance in feet (or meters) from the blast site to the nearest dwelling, public building, school, church, commercial, or institutional building normally occupied not owned, leased, or contracted by the blasting operation, or on property where the owner has not given a written waiver to the blasting operation. Note : To convert English Units of scaled distances (ft/lb1/2) to metric units (m/kg1/2) divide by a factor of 2.21. Table 2: STANDARD TABLE OF DISTANCE (0 to 300 feet (91.4 m)) Distance in Feet Weight in Pounds 0-10 1/8 11-15 1/4 16-20 1/2 21-25 3/4 26-30 1.00 40 2.25 50 3.50 60 4.75 70 6.00 80 7.25 90 8.50 100 9.75 110 11.00 130 13.50 150 16.00 170 18.50 190 21.00 210 23.50 230 26.00 250 28.50 270 31.00 290 33.50 300 34.75 (c) Airblast resulting from blasting activities must not exceed one hundred forty decibels (140 dB) at the location of a dwelling, public building, school, church, or commercial or institutional building that is not owned or leased by the person engaged in the blasting operation, or on property for which the owner has not provided a written waiver to the person engaged in the blasting operation. (d) In estimating the peak particle velocity at a particular position, the following equation must be used: Click here to view formula. In the equation, V 0 is the maximum ground particle velocity at the seismograph, D 0 is the distance of the seismograph from the blasting, and D is the distance from the blast to the position in question and in the same general direction. The distance D 0 may not be greater than D, and D cannot be more than five (5) times D 0 . (e) Blasting operations at permanent sites are considered as being within the limits set forth in this section if at specified locations, on at least five (5) blasts, instrumentation has shown the peak particle velocity and frequency to be within the limits of Figure A. Periodic seismic monitoring must be employed to ensure compliance with applicable law.