South Carolina Statutes

§ 5-25-900 — Firestopping construction on floor levels.

South Carolina·Title 5 MUNICIPAL CORPORATIONS·Ch. 25 BUILDING CODES AND FIRE PREVENTION
At each floor level, in all buildings erected after February 20 1917 all stud walls, partitions, furrings and spaces between joists, where they rest on division walls or partitions, shall be firestopped with incombustible material in a manner to cut off completely communication by fire through concealed spaces. Such firestopping shall extend the full depth of the joists and at least four inches above each floor level. Stair carriages shall be firestopped at least once in the middle portion of each run.

Free access — add to your briefcase to read the full text and ask questions with AI

South Carolina § 5-25-900 (Firestopping construction on floor levels.) — published by Counsel Stack Legal Research, free access to 12M+ legal documents.

Legislative History

HISTORY: 1962 Code SECTION 47-1257; 1952 Code SECTION 47-1257; 1942 Code SECTION 7521; 1932 Code SECTION 7521; Civ. C. '22 SECTION 4636; 1917 (30) 77.