§ 5-25-900 — Firestopping construction on floor levels.

South Carolina § 5-25-900
JurisdictionSouth Carolina
Title 5MUNICIPAL CORPORATIONS
Ch. 25BUILDING CODES AND FIRE PREVENTION

This text of South Carolina § 5-25-900 (Firestopping construction on floor levels.) is published on Counsel Stack Legal Research, covering South Carolina primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
S.C. Code Ann. § 5-25-900 (2026).

Text

At each floor level, in all buildings erected after February 20 1917 all stud walls, partitions, furrings and spaces between joists, where they rest on division walls or partitions, shall be firestopped with incombustible material in a manner to cut off completely communication by fire through concealed spaces. Such firestopping shall extend the full depth of the joists and at least four inches above each floor level. Stair carriages shall be firestopped at least once in the middle portion of each run.

Free access — add to your briefcase to read the full text and ask questions with AI

Legislative History

HISTORY: 1962 Code SECTION 47-1257; 1952 Code SECTION 47-1257; 1942 Code SECTION 7521; 1932 Code SECTION 7521; Civ. C. '22 SECTION 4636; 1917 (30) 77.