South Carolina Statutes

§ 5-25-890 — Stairways; exit doors.

South Carolina § 5-25-890
JurisdictionSouth Carolina
Title 5MUNICIPAL CORPORATIONS
Ch. 25BUILDING CODES AND FIRE PREVENTION

This text of South Carolina § 5-25-890 (Stairways; exit doors.) is published on Counsel Stack Legal Research, covering South Carolina primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
S.C. Code Ann. § 5-25-890 (2026).

Text

Except in dwellings, no required stairway shall be less than forty-four inches wide and the total width of exit doorways leading therefrom shall at least be equal to the total width of the stairways which they serve. The total width of stairway, interior and exterior, provided for the occupancy of each floor and those above, shall be not less than forty-four inches for the first fifty persons and twelve inches for each additional fifty persons to be accommodated thereby. The stair treads shall be not less than nine and one-half inches wide and the risers not more than seven and three-fourths inches high. Windows in any such required stairway are prohibited. Every hospital and theater over one story high shall have at least two stairways constructed entirely of incombustible material, locat

Free access — add to your briefcase to read the full text and ask questions with AI

Legislative History

HISTORY: 1962 Code SECTION 47-1256; 1952 Code SECTION 47-1256; 1942 Code SECTION 7520; 1932 Code SECTION 7520; Civ. C. '22 SECTION 4635; 1917 (30) 77.

Nearby Sections

15
View on official source ↗

Cite This Page — Counsel Stack

Bluebook (online)
South Carolina § 5-25-890, Counsel Stack Legal Research, https://law.counselstack.com/statute/sc/25/5-25-890.