Except in dwellings, no required stairway shall be less than forty-four inches wide and the total width of exit doorways leading therefrom shall at least be equal to the total width of the stairways which they serve. The total width of stairway, interior and exterior, provided for the occupancy of each floor and those above, shall be not less than forty-four inches for the first fifty persons and twelve inches for each additional fifty persons to be accommodated thereby. The stair treads shall be not less than nine and one-half inches wide and the risers not more than seven and three-fourths inches high. Windows in any such required stairway are prohibited. Every hospital and theater over one story high shall have at least two stairways constructed entirely of incombustible material, locat
Free access — add to your briefcase to read the full text and ask questions with AI
Legislative History
HISTORY: 1962 Code SECTION 47-1256; 1952 Code SECTION 47-1256; 1942 Code SECTION 7520; 1932 Code SECTION 7520; Civ. C. '22 SECTION 4635; 1917 (30) 77.
Nearby Sections
15
§ 5-25-10
Application of chapter.§ 5-25-110
Chief of fire department.§ 5-25-1150
Repairs to roofs within fire limits.§ 5-25-1160
Removal of damaged frame buildings.§ 5-25-120
Inspectors of buildings.§ 5-25-130
Deputy building inspector.Cite This Page — Counsel Stack
Bluebook (online)
South Carolina § 5-25-890, Counsel Stack Legal Research, https://law.counselstack.com/statute/sc/25/5-25-890.