§ 5-25-760 — Ranges and stoves.

South Carolina § 5-25-760
JurisdictionSouth Carolina
Title 5MUNICIPAL CORPORATIONS
Ch. 25BUILDING CODES AND FIRE PREVENTION

This text of South Carolina § 5-25-760 (Ranges and stoves.) is published on Counsel Stack Legal Research, covering South Carolina primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
S.C. Code Ann. § 5-25-760 (2026).

Text

No kitchen range or stove in any building shall be placed less than three feet from any woodwork or wooden lath and plaster partition, unless the woodwork or partition is properly protected by metal shields, in which case the distance shall be not less than eighteen inches. Metal shields shall be loosely attached, thus preserving an air space behind them. Hotel and restaurant ranges shall be provided with a metal hood, placed at least nine inches below any wooden lath and plaster or wooden ceiling, and have an individual pipe outlet connected with a good thick flue. The pipe shall be protected by at least one inch of asbestos covering or its equivalent.

Free access — add to your briefcase to read the full text and ask questions with AI

Legislative History

HISTORY: 1962 Code SECTION 47-1243; 1952 Code SECTION 47-1243; 1942 Code SECTION 7511; 1932 Code SECTION 7511; Civ. C. '22 SECTION 4626; 1917 (30) 77.