§ 5-25-650 — Structures around chimneys, flues and fireplaces.
South Carolina § 5-25-650
This text of South Carolina § 5-25-650 (Structures around chimneys, flues and fireplaces.) is published on Counsel Stack Legal Research, covering South Carolina primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.
Bluebook
S.C. Code Ann. § 5-25-650 (2026).
Text
No wooden beams or joists shall be placed within two inches of the outside face of a chimney or flue, whether it be for smoke, air or any other purpose. No woodwork shall be within four inches of the back wall of any fireplace. All spaces between the chimney and the wooden beams shall be solidly filled with mortar, mineral wool or other incombustible material. The header beam, carrying the tail beams of a floor and supporting the timber arch in front of a fireplace, shall be not less than twenty inches from the chimney breast. No wooden furring or studding shall be placed against any chimney but the plastering shall be directly on the masonry or on metal lathing. Woodwork fastened to plaster which is against the masonry of a chimney shall have a layer of asbestos board at least one-eighth
Free access — add to your briefcase to read the full text and ask questions with AI
Legislative History
HISTORY: 1962 Code SECTION 47-1232; 1952 Code SECTION 47-1232; 1942 Code SECTION 7502; 1932 Code SECTION 7502; Civ. C. '22 SECTION 4617; 1917 (30) 77.
Nearby Sections
15
§ 5-25-10
Application of chapter.§ 5-25-110
Chief of fire department.§ 5-25-1150
Repairs to roofs within fire limits.§ 5-25-1160
Removal of damaged frame buildings.§ 5-25-120
Inspectors of buildings.§ 5-25-130
Deputy building inspector.Cite This Page — Counsel Stack
Bluebook (online)
South Carolina § 5-25-650, Counsel Stack Legal Research, https://law.counselstack.com/statute/sc/25/5-25-650.