No opening in any interior masonry wall shall exceed eight feet by ten feet. If the opening be in a party or fire wall, it shall have a standard automatic fire door on each side of the wall. If an opening in a fire wall is made to serve as an emergency exit, it shall not exceed forty-eight square feet in area and a self-closing fire door shall be substituted for one of the automatic fire doors. The total openings in a fire wall shall not exceed twenty-five per cent in lineal length of the wall. Every building within the fire limits, except churches, dwellings, tenement houses, dormitories and lodging houses, shall have standard fire doors, shutters or wired glass in incombustible frames and sashes on every exterior opening above the first story, except when fronting on a street not less th

Free access — add to your briefcase to read the full text and ask questions with AI

South Carolina § 5-25-630 (Openings in walls; standard fire doors; windows.) — published by Counsel Stack Legal Research, free access to 12M+ legal documents.

Legislative History

HISTORY: 1962 Code SECTION 47-1229; 1952 Code SECTION 47-1229; 1942 Code SECTION 7499; 1932 Code SECTION 7499; Civ. C. '22 SECTION 4614; 1917 (30) 77.