(1)Any temporary or permanent guyed tower fifty (50) feet or more in height that is located outside the boundaries of an incorporated city or town on land that is primarily rural or undeveloped or used for agricultural purposes, or that is primarily desert, and where such guyed tower’s appearance is not otherwise governed by state or federal law, rule or regulation, shall be lighted, marked and painted or otherwise constructed to be visible in clear air during daylight hours from a distance of not less than two thousand (2,000) feet. Guyed towers shall be required to be in accordance with the following:
(a)Guyed towers shall be painted in seven equal alternating bands of aviation orange and white. Such alternating bands shall begin with orange at the top of the tower and end with orange