Willett v. Baxter International, Inc.

929 F.2d 1094, 1991 U.S. App. LEXIS 7865, 1991 WL 55058
CourtCourt of Appeals for the Fifth Circuit
DecidedMay 1, 1991
DocketNo. 90-3418
StatusPublished
Cited by76 cases

This text of 929 F.2d 1094 (Willett v. Baxter International, Inc.) is published on Counsel Stack Legal Research, covering Court of Appeals for the Fifth Circuit primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Willett v. Baxter International, Inc., 929 F.2d 1094, 1991 U.S. App. LEXIS 7865, 1991 WL 55058 (5th Cir. 1991).

Opinion

WISDOM, Circuit Judge:

The plaintiff, Gene Earl Willett, sued the defendants, Baxter Healthcare Corporation (“Baxter”) and Carbomedics, Inc., seeking to recover for his fear that his allegedly defective heart valve, manufactured by the defendants, would fail.1 Mrs. Albert Sprig-gins, and her husband, intervened in the action, seeking the same recovery. Upon the motion of the defendants, the district court granted summary judgment in favor of the defendants holding that the valves of the plaintiff and the intervenor were not defective and that Louisiana did not recognize a right of recovery for the fear that the valves may fail in the future. While we disagree with some of the reasoning of the district court, we AFFIRM because the plaintiff, and the intervenor, have failed to present sufficient evidence to enable a reasonable jury to find that the valves were defective.

I

In January of 1988, Dr. White E. Gibson III, a New Orleans cardiovascular surgeon, replaced deteriorating heart valves in both Willett and Mrs. Spriggins with artificial heart valves manufactured by the defendants.2 In June of 1988, Willett read an article in his local paper that discussed Baxter’s voluntary suspension of the mar[1096]*1096keting of the valves. Willett filed this action less than a week later. After reading of the lawsuit in the paper, Mrs. Willett and her husband intervened.

Each artificial heart valve has two leaves, made of pyrolitic carbon, that control the flow of blood through the valve. The voluntary recall was prompted by several reports of a phenomenon known as “leaflet escape”. Leaflet escape refers to the in vivo escape of one of the two leaflets that controls the flow of blood through the valve.

The plaintiff and the intervenor alleged that their valves were defective in that pyrolitic carbon was not well-suited for use in heart valves because of the possibility of stress fractures in the material. The plaintiff and the intervenor do not deny that their valves are currently functioning properly. Instead, they seek damages for their fear that their valves will fail in the future.

After a suitable time for discovery, the defendants moved for summary judgment. To support the motion, the defendants filed the affidavits of Dr. Gibson, the surgeon who performed the operations, and Mr. William G. Swartz, an epidemiologist employed by Baxter. The plaintiff, and the intervenor, responded with sealed documents obtained from another court case involving the valves.3 The plaintiff and the intervenor argue that these documents establish that pyrolitic carbon is an inappropriate material for use in heart valves.

Taken together, the summary judgment evidence established that approximately 19,614 patients received these valves between 1982 and the first quarter of 1990. Since the valves were first implanted, only seventeen cases of leaflet escape have been reported. Of the seventeen reported cases, fifteen involved mitral valves, and two involved aortic valves. All seventeen cases occurred in valves manufactured before April of 1986. The valves of both the plaintiff and the intervenor were manufactured after April of 1986. Of the valves manufactured since April of 1986, no failures have been reported.4

From the evidence, a reasonable jury could conclude that leaflet escape is caused by stress fractures in the pyrolitic carbon. From the evidence, it appears that pyrolitic carbon is very resistant to the start of a stress fracture. But once a stress fracture has begun, the fracture will grow at a fairly steady rate, and may eventually lead to leaflet escape.

Baxter published at least three Clinical Reports documenting the leaflet escape problem in January of 1987, November of 1987, and January of 1988. The articles described the failures that had occurred to date. While the reports stated that the cause (or causes) of the failures was uncertain, the articles suggested that the problem may have been caused by improper surgical technique. Specifically, the reports suggested that, during the surgical procedure, a valve may have been scratched or improperly exposed to certain chemicals. This scratch or improper exposure created a weak spot in the leaflet, where a stress fracture could begin.

In contrast, the plaintiff and the inter-venor argue that the manufacturing process inevitably leads to weak spots in the leaflets. They rely on the deposition testimony of one Dr. Harvey Miller Flower, taken from the sealed court records. According to Dr. Flower, soot pockets can form in pyrolitic carbon during manufacture. If not discovered, the soot pocket might weaken the leaflet sufficiently that a stress fracture can begin. Notably, the expert did not testify that another material was more suitable than pyrolitic carbon for use in the valves, or that a different manu[1097]*1097facturing or quality control process could have reduced a theoretical soot pocket problem. Dr. Flower also did not testify as to how often undiscovered soot pockets would develop given the manufacturing and quality control process used by the defendants.

The plaintiff and the intervenor provided no evidence that their particular valves actually suffered from a soot pocket problem, and no evidence that their valves were not performing as designed. On the contrary, their surgeon, Dr. Gibson stated, in his affidavit, that the valves implanted in both Willett and Mrs. Spriggins were functioning normally. He also stated that, to a reasonable degree of medical certainty, the valve replacement had saved their lives and greatly improved their quality of life.

The district court granted summary judgment in favor of the defendants. The district court held that the valves were functioning normally and were therefore not defective, and that Louisiana did not recognize a cause of action for the fear that the valves would become defective. The plaintiff and the intervenor have appealed arguing that the valves can be defective even though they have not yet failed, and that their fear and mental anguish should be recognized as a cognizable injury under Louisiana law.

II

To recover under Louisiana products liability law, a plaintiff must show: (1) that the product was defective and (2) that the defective aspect of the product caused a legally cognizable injury to the plaintiff.5 A plaintiff may show that a product is defective by showing that:

(1)the product is unreasonably dangerous per se; or
(2) the product was defectively manufactured; or
(3) the product was defectively designed; or
(4) the manufacturer failed to warn of a non-obvious danger inherent in the normal use of the product.6

While the question of whether a product is defective is ordinarily one of fact,7 to avoid summary judgment, the plaintiff and the intervenor must point to sufficient evidence in the record to make the fact issue a genuine one.8 If there is insufficient evidence to enable a reasonable jury to find that the heart valves were defective, then we must affirm the district court’s decision. We consider each possible defect theory in turn.

First, to establish that a product is unreasonably dangerous per se,

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Smith v. Depuy Synthes Inc.
E.D. Louisiana, 2025
Holloway v. Abbvie Inc.
M.D. Louisiana, 2024
Banks v. C.R. Bard, Inc.
M.D. Louisiana, 2022
Womack v. A B C Insurance Co
W.D. Louisiana, 2022
Meade v. Ethicon, Inc.
E.D. Arkansas, 2021
Couturier v. C.R. Bard Inc.
E.D. Louisiana, 2021
Celino v. Biotronik Inc
E.D. Louisiana, 2021
Sharp v. Ethicon, Inc.
W.D. Arkansas, 2020
Oliver v. Covidien LP
E.D. Louisiana, 2020
Shepard v. Johnson & Johnson
W.D. Louisiana, 2019
Barber v. Spinal Elements
E.D. Louisiana, 2019
Nowell v. Medtronic Inc.
372 F. Supp. 3d 1166 (D. New Mexico, 2019)

Cite This Page — Counsel Stack

Bluebook (online)
929 F.2d 1094, 1991 U.S. App. LEXIS 7865, 1991 WL 55058, Counsel Stack Legal Research, https://law.counselstack.com/opinion/willett-v-baxter-international-inc-ca5-1991.