Smithkline Diagnostics, Inc. v. Helena Laboratories Corp.

662 F. Supp. 622
CourtDistrict Court, E.D. Texas
DecidedJune 19, 1987
DocketCiv. A. B-83-10-CA
StatusPublished
Cited by3 cases

This text of 662 F. Supp. 622 (Smithkline Diagnostics, Inc. v. Helena Laboratories Corp.) is published on Counsel Stack Legal Research, covering District Court, E.D. Texas primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Smithkline Diagnostics, Inc. v. Helena Laboratories Corp., 662 F. Supp. 622 (E.D. Tex. 1987).

Opinion

FINDINGS OF FACT AND CONCLUSIONS OF LAW

JOE J. FISHER, District Judge.

The above-entitled and numbered cause came on for trial, and the Court having considered the pleadings, having heard the testimony and determined the credibility of witnesses, having examined physical exhibits and studied post-trial submissions of the parties, and all of the evidence, and having heard the arguments and reviewed the briefs of counsel, now makes the following Findings of Fact and Conclusions of Law pursuant to Rule 52, Federal Rules of Civil Procedure. If any Finding of Fact should be construed as a Conclusion of Law, it is to be so considered; and should any Conclusion of Law be construed as a Finding of Fact, it is to be so considered.

FINDINGS OF FACT

1.

This is a suit for infringement of U.S. Patent No. 4,365,970 (the Lawrence patent or the ’970 patent) brought by SmithKline Diagnostics, Inc. (SKD) against Helena Laboratories Corporation (Helena).

2.

SKD owns patent in suit No. 4,365,970 to a diagnostic test for detecting occult blood in fecal matter.

3.

The test is known as a fecal specimen test slide. It includes paper containing a compound, guaiac, that turns blue in the presence of a developing solution and a catalyst, such as the hemoglobin in blood. Thus, a blue color indicates the presence of blood and is referred to as a “positive” result. The absence of blue indicates the absence of blood and is referred to as a “negative” result. It is important to verify that the guaiac paper and the developing solution are working properly. False negative or positive results can cause failure to detect colorectal cancer or unnecessary, exhaustive clinical investigations and patient anxiety.

4.

The ’970 patent discloses and claims the first fecal occult blood specimen test slide having built-in positive and negative monitors for verifying the proper performance of the slide. The slide contains, besides the test area where the fecal specimen is applied, an isolated area divided into two sections. One additionally contains a catalyst — a compound that reacts to environmental conditions in a manner similar to hemoglobin — is the positive monitor. The second section lacks the catalyst and consists of the guaiac-impregnated paper alone, and is the negative monitor.

5.

After developer is added to the paper opposite the fecal specimen, developer is added to the positive and negative monitors. A blue color on the positive monitor means the reagents are working properly. The absence of a blue color on the negative monitor means the slide has not been contaminated.

6.

The invention of the ’970 patent satisfied a long-felt need for a satisfactory built-in test for verifying the performance of fecal occult blood test slides. This need was recognized as early as the 1950’s in a publication calling for use of external controls. External controls have been virtually unused because they are cumbersome. Nevertheless, they went essentially unchanged for thirty years.

7.

External controls had other, serious deficiencies. They were generally used as a “batch test,” i.e. once for each batch of *625 samples, which left the possibility of contamination or other error that did not affect the whole batch. Doctors that inquired about testing the slides were advised only to use a dilute blood solution as a positive control. Negative controls that would detect false positives were not suggested. Furthermore, the slides were used by people unskilled in the techniques necessary to make, store, and use controls. Despite the critical need for controls that worked, those looking for a solution to the problem experimented only with external controls.

8.

Dr. Lawrence of SKD, a coinventor of the ’970 patent, followed a different approach, namely, built-in positive and negative controls on each slide. This had the advantage of verifying the performance of every slide and it was much easier to use than external controls. Furthermore, a built-in positive monitor printed during manufacturing gave more reproducible results than external controls that were applied in variable amounts. Dr. Lawrence’s approach was also new in that he no longer sought only controls that simulated feces. Monitors that indicated only whether the slide and developer were working properly avoided the confusion that could result from comparing the test results on the actual fecal specimen and on the monitors.

9.

Dr. Lawrence experimented to test his ideas. By February 23, 1979, Dr. Lawrence had conceived of the definite and permanent idea of the complete and operative fecal occult blood test slide with built-in monitors that was later specified in claim 1 of the ’970 patent and used in SKD’s Hemoccult slides, as evidenced by his laboratory notebook and written and oral reports and demonstrations to Mr. S. Wayne Kay, who corroborated Dr. Lawrence’s testimony. Dr. Lawrence had done enough work by February 23, 1979 to know that his basic concept worked satisfactorily.

10.

Claims 1, 2, 4 and 5 are alleged to be infringed (35 U.S.C. § 271) by Helena’s Co-loscreen products. Helena has denied infringement and counterclaimed for a declaration of noninfringement and patent invalidity for obviousness. (35 U.S.C. § 103). Much of the evidence relating to the issues of validity and infringement involved the proper interpretation of the phrase “reacts to environmental conditions in a manner similar to hemoglobin” which appears not only in the patent specification but in all of the asserted claims.

11.

The subject matter of this lawsuit is a product including a chemical test for fecal occult blood testing. Chemical tests of stool samples for occult blood was a well-known technique for many years prior to the Lawrence patent.

For many years, SKD marketed a paper “slide” under the trademark “Hemoccult”. The Hemoccult slide contained locations for one or more stool samples.

12.

In 1980, Helena, in connection with its Coloscreen slides, supplied a control system under the trademark “Colochek,” which allowed verification that the chemicals were functioning properly. Helena advertised and marketed the use of the control system on each slide. The control system marketed by Helena “looked like” the fecal specimen and the positive control included hemoglobin.

By 1980, Gamma Biologicals, of Houston, was also marketing a competitive slide product with a control system including hemoglobin as the positive control.

13.

According to the Lawrence patent description, because of the possibility of false results, controls should be provided for each slide. The positive control should turn color if everything was working properly and the negative control should remain colorless (no color change) if everything was working properly.

Free access — add to your briefcase to read the full text and ask questions with AI