Morris v. Biomet Orthopedics LLC

CourtDistrict Court, D. Maryland
DecidedSeptember 30, 2020
Docket1:18-cv-02440
StatusUnknown

This text of Morris v. Biomet Orthopedics LLC (Morris v. Biomet Orthopedics LLC) is published on Counsel Stack Legal Research, covering District Court, D. Maryland primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Morris v. Biomet Orthopedics LLC, (D. Md. 2020).

Opinion

IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF MARYLAND Southern Division

CHARLOTTE MORRIS, *

Plaintiff, * v. Case No.: GJH-18-2440 * BIOMET, INC., et al., * Defendant. * * * * * * * * * * * * * *

MEMORANDUM OPINION

Plaintiff Charlotte Morris brought this products liability action against Defendants Biomet Orthopedics, LLC, Biomet, Inc. Biomet Manufacturing LLC f/k/a Biomet Manufacturing Corps., and Biomet U.S. Reconstruction, LLC (collectively, “Biomet”) based on injuries related to an artificial hip implant manufactured by Biomet that was used during Plaintiff’s February 2008 right total hip replacement surgery. ECF No. 1. Specifically, Plaintiff alleges claims of manufacturing defect, failure to warn, negligence, design defect, fraudulent concealment, breach of implied warranties, breach of express warranty, and punitive damages. Id. Currently pending before the Court are Biomet’s Motion to Exclude Plaintiff’s Expert John I. Waldrop, M.D. (“Motion to Exclude Expert Testimony”), ECF No. 226, and Biomet’s Motion for Summary Judgment, ECF No. 228.1 No hearing is necessary to resolve the pending motions. See Loc. R. 105.6 (D. Md. 2018). For the following reasons, Biomet’s Motion to Exclude Expert Testimony

1 Also pending before the Court are Plaintiff’s Motions to Compel Discovery, ECF Nos. 235, 239, and Biomet’s Motion to Strike Certification of Conference or in the Alternative Motion to Narrow Issues, ECF No. 240. On August 14, 2020, the parties filed a Joint Notice of Potential Mootness of Pending Motions informing the Court that, on August 10, 2020, the MDL Court entered an order addressing the issues raised by these Motions, thus potentially rendering them moot, and asking the Court to withhold any ruling on the Motions. ECF No. 246. Subsequently, the parties filed a status report requesting that the motions be withdrawn. ECF No. 24. The Court will find that the Motions are rendered Moot. is granted, in part, and denied, in part, and Biomet’s Motion for Summary Judgment is granted, in part, and denied, in part. I. BACKGROUND2 A. Total Right Hip Replacement Surgery On March 19, 2002, Plaintiff sought treatment from Dr. Michael A. Jacobs for left hip,

knee, and back pain. ECF No. 228-3 at 2–3.3 Dr. Jacobs diagnosed Plaintiff with significant degenerative joint disease of the left hip and degenerative disc disease in the L-spine, and he recommended a left total hip replacement. Id. at 3. On June 19, 2002, at MedStar Good Samaritan Hospital, Dr. Jacobs performed a total left hip replacement on Plaintiff, for which he chose a DePuy metal-on-metal hip implant. Id. at 4–6. On November 8, 2005, Plaintiff sought treatment from Dr. Jacobs for right lower back and buttock pain, id. at 7, and in November 2007, Dr. Jacobs observed end-stage osteoarthritis in Plaintiff’s right hip and symptoms of spinal stenosis and stiffness in her back, and he recommended surgery, id. at 8. On February 6, 2008, at MedStar Good Samaritan Hospital, Dr.

Jacobs performed a right hip replacement on Plaintiff for which he chose a Biomet M2a Magnum metal-on-metal hip implant (the “Biomet Device”). Id. at 9–10. Plaintiff did not participate in the selection of her implant and trusted Dr. Jacobs to choose the device. ECF No. 228-4 at 3. B. The Biomet Device The Biomet Device is a metal-on-metal hip joint replacement. See ECF No. 228-7 at 2. It contains three components: a femoral head, a taper insert, and an acetabular cup. Id. The head

2 These facts are either undisputed or viewed in the light most favorable to Plaintiff as the non-moving party. 3 Pin cites to documents filed on the Court’s electronic filing system (CM/ECF) refer to the page numbers generated by that system. and acetabular cup components are made from cobalt chrome molybdenum (CoCrMo) alloy, and the taper insert is made of a titanium alloy. See id. The acetabular cup, which is seated in the hip, is treated with a porous coating of titanium alloy. Id. Biomet included a package insert, or Instructions for Use (“IFU”), with the Biomet Device. See ECF No. 228-7. The IFU for Plaintiff’s Biomet Device included possible adverse

effects of using the device, including: 1. Material sensitivity reactions. Implantation of foreign material in tissues may result in histological reactions involving various sizes of macrophages and fibroblasts. The clinical significance of this effect is uncertain, as similar changes may occur as a precursor to or during the healing process. Particulate wear debris and dislocation from metallic and polyethylene components of joint implants may be present in adjacent tissue or fluid. It has been reported that wear debris may initiate a cellular response resulting in osteolysis or osteolysis may be a result of loosening of the implant. Further, there has been a report regarding an association between articulating surfaces of: 1) CoCrMo alloy on CoCrMo alow, 2) CoCrMo alloy on polyethylene, and 3) Titanium alloy on polyethylene in hip replacements and increased genotoxicity. This report, however, did not assess either the clinical relevance of the data or make any definite conclusions as to which metal ions or interactions between metal ions or particulate metals might be responsible for the observed data. The report further cautioned that an association does not necessarily mean a causal relationship, and that any potentially increased risk associated with metal ions needs to be balanced against the benefits resulting from the hip replacement. A low incidence of metal hypersensitivity has been reported with failed metal-on-metal implants. The clinical relevance of these findings is unclear, and it is not known whether metal hypersensitivity causes implant failure.

2. Early or late postoperative infection and allergic reaction.

4. Loosening or migration of the implants may occur due to loss of fixation, trauma, malalignment, bone resorption, or excessive activity.

10. Fretting and crevice corrosion may occur at interfaces between components.

11. Wear and/or deformation of articulating surfaces.

15. Elevated metal ion levels have been reported with metal-on-metal articulating surfaces. Although mechanical testing demonstrates that metal-on-metal articulating surfaces produce a relatively low amount of particles, the total amount of particulate produced in vivo throughout the service life of the implants remains undetermined. The long-term biological effects of the particulate and metal ions are unknown.

ECF No. 228-7 at 2. Dr. Jacobs does not specifically recall whether he read the IFU prior to Plaintiff’s implantation surgery, ECF No. 228-8 at 7–8, but it was his standard practice to familiarize himself generally with the indications received from the manufacturer, such as the surgical technique, which would include reviewing the IFU, id. at 4. C. Revision Surgery After Plaintiff’s right hip surgery, Dr. Jacobs continued to see her once a year for routine follow-up appointments. ECF No. 228-8 at 5. On September 9, 2010, approximately two and a half years after her surgery, Plaintiff complained of right hip clicking, which Dr. Jacobs was able to reproduce upon examination. ECF No. 228-3 at 14. At the time of his examination, Dr. Jacobs suspected that the clicking was a soft tissue band catching. Id. The treatment plan involved seeing Plaintiff in a year if she was asymptomatic, but if the clicking became a problem or she developed any further symptoms, she was to have Dr. Jacobs evaluate her sooner. Id. On September 19, 2011, Dr. Davis Hahn, Plaintiff’s oncologist, ordered her to undergo a CT scan of her abdomen and pelvis, which showed a low-density fluid collection, or pseudotumor, near her right iliopsoas muscle. Id. at 15–16. Dr. Hahn noted that “it seems fairly clear that Mr.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Anderson v. Liberty Lobby, Inc.
477 U.S. 242 (Supreme Court, 1986)
Daubert v. Merrell Dow Pharmaceuticals, Inc.
509 U.S. 579 (Supreme Court, 1993)
United States v. Bynum
604 F.3d 161 (Fourth Circuit, 2010)
Margaret Scott v. Sears, Roebuck & Company
789 F.2d 1052 (Fourth Circuit, 1986)
McClure v. Scientific Spinal
11 F. App'x 154 (Fourth Circuit, 2001)
Harford Mutual Insurance v. Apria Healthcare, Inc.
159 F. App'x 479 (Fourth Circuit, 2005)
Pugh v. Louisville Ladder, Incorporated
361 F. App'x 448 (Fourth Circuit, 2010)
Witherspoon v. Philip Morris Inc.
964 F. Supp. 455 (District of Columbia, 1997)
Lee v. Baxter Healthcare Corp.
721 F. Supp. 89 (D. Maryland, 1989)
Nova Research, Inc. v. Penske Truck Leasing Co.
952 A.2d 275 (Court of Appeals of Maryland, 2008)
Lynx, Inc. v. Ordnance Products, Inc.
327 A.2d 502 (Court of Appeals of Maryland, 1974)
Maryland National Bank v. Resolution Trust Corp.
895 F. Supp. 762 (D. Maryland, 1995)
Gourdine v. Crews
955 A.2d 769 (Court of Appeals of Maryland, 2008)
Rite Aid Corp. v. Levy-Gray
876 A.2d 115 (Court of Special Appeals of Maryland, 2005)
Ames v. Apothecon, Inc.
431 F. Supp. 2d 566 (D. Maryland, 2006)

Cite This Page — Counsel Stack

Bluebook (online)
Morris v. Biomet Orthopedics LLC, Counsel Stack Legal Research, https://law.counselstack.com/opinion/morris-v-biomet-orthopedics-llc-mdd-2020.