Morgan v. Metropolitan Fuels, Inc.

334 A.2d 553, 25 Md. App. 598, 1975 Md. App. LEXIS 553
CourtCourt of Special Appeals of Maryland
DecidedApril 8, 1975
DocketNo. 732
StatusPublished

This text of 334 A.2d 553 (Morgan v. Metropolitan Fuels, Inc.) is published on Counsel Stack Legal Research, covering Court of Special Appeals of Maryland primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Morgan v. Metropolitan Fuels, Inc., 334 A.2d 553, 25 Md. App. 598, 1975 Md. App. LEXIS 553 (Md. Ct. App. 1975).

Opinion

Lowe, J.,

delivered the opinion of the Court.

The relatively new home of Ivan and Harriet Morgan, appellants, burned to the ground approximately one year after they occupied it. Ivan Morgan, a carpenter by trade, had constructed his home in Potomac, Maryland. Having built other homes he chose to act as his own contractor and let subcontracts for the various phases of the work. Among those subcontractors was Movalco, Inc., which subcontracted for the design and installation of the heating system.

The two furnaces installed were vented by a stack pipe approximately six feet long, about four feet of which paralleled in close proximity the floor joists supporting the first floor den. Although the joists were covered with a basement ceiling composed of sheet rock or gypsum board described as fireproof, testimony indicated that the exhaust vent pipes were within five inches of the floor joists. From a plethora of expert testimony it would be fair to summarize the opinions expressed as agreeing that eighteen inches was the preferred minimum safe distance such exhaust pipes should be located from combustible material unless a heat shield was installed between the pipes and the combustible materials (wood joists in this instance). No such shield was installed. It was further testified that discharged flue gasses in the stack pipe from furnace to chimney, coupled with the room temperature, would fluctuate between 570 and 670 [600]*600degrees gross temperature which exceeds that necessary to ignite the combustible joists. The lapse of time of approximately one year between installation and the burning of the building was explained as being the length of time necessary for the wood in the floor joists to dry out completely.

Suffice to say that the evidence was ample for a jury to conclude that the fire was caused by the close proximity of the exhaust stack pipes to the combustible wooden floor joists. It is not surprising then that a Montgomery County jury delivered a verdict favorable to the Morgans and against Movalco, Inc. which, after second thoughts, has dismissed its appeal from the judgment rendered on that verdict by Judge Shure of the Circuit Court for Montgomery County. Movalco has appealed, however, (as do the Morgans) from a judgment n.o.v. granted by Judge Shure in favor of Movalco’s co-defendant below, Metropolitan Fuels, Inc.1

Metropolitan had been engaged by Movalco to install the fuel tank, run the oil lines from tank to furnace, make all oil line connections, make all electrical connections, and finally, to start the furnace “to make sure it ran properly.” It was admitted on behalf of Metropolitan that “when the employee is there to check out the system and to see if it is running properly, he is to determine if it will run safely so as not to create a fire hazard.” The scope of the “duty” owed by Metropolitan to the appellants is the focal point on appeal.

[601]*601Appellants contend that appellee Metropolitan owed the Morgans a duty which arose from the fact that Metropolitan contractually undertook to perform a service. Appellants acknowledge that such duty does not arise because of the entry into the contract, but rather having undertaken “to see if [the furnace] will run properly . . . [and] . . . safely . . .” Metropolitan assumed liability “for physical harm resulting from [its] failure to exercise reasonable care to perform [its] undertaking . . .”. Restatement of Torts, Second, § 323. They analogize an example given by Professor Prosser in his work on Torts, (4th ed.) § 56, at 347 of a “landlord who makes repairs on leased premises, although he is under no obligation to do so . . . .” Professor Prosser states that the landlord in that case “assumes a duty to his tenant ... to exercise proper care to see that the repairs are safe, or at least that the tenant is not left in ignorance of the danger.”

While the trip was somewhat circuitous, appellants now arrive at their destination. Their argument thus far seems to imply a duty on Metropolitan to investigate all aspects of the initial installation by Movalco. Not necessary, say appellants. The service men for Metropolitan who actually fired the furnace for its test run admitted seeing the pipe and, it follows by implication, the pipe’s proximity to the cellar ceiling joists. “I didn’t even think about it. I just looked up and the chimney was hooked up and that was all I was concerned about,” said the service attendant. Appellants note that Metropolitan’s President had expressed an opinion based upon thirty years experience that the flue pipe should not have been closer than eighteen inches to the floor joists. They then attempt to link that testimony with the service attendant’s actual observation of the five inch differential. Their conclusion: there was a duty on Metropolitan to inform appellants of the faulty installation by Movalco. Having failed to warn them appellants say, Metropolitan breached its duty and must share the blame and the $125,000 judgment with Movalco.

Appellants argue further that they hardly need have taken the longer route of finding a duty from an assumed undertaking, but rather could have relied upon a Court of [602]*602Appeals opinion remarkably similar factually, Klein v. Dougherty, et al., 200 Md. 22. The “et al.” appellee there was the “Allied Oil Burner Service.” The facts are concisely recited at 26:

“Milton Klein and wife constructed a home on Wirt Avenue in Baltimore. He acted as general contractor and let subcontracts for the various phases of the work. When the furnace was installed by Mr. Andrew Dougherty, the smoke pipe was put in a hole in the chimney without a hole being cut through the tile lining of the chimney. When the furnace was started by Allied Oil Burner Service there was no way for the smoke to escape in the chimney. When Mr. Klein, the appellant, drove by the house he saw smoke coming from an exhaust vent in the kitchen. Upon investigation it was found that the interior of the house was covered with soot. As a result, the equitable plaintiff paid the Kleins $1,100.00, and suit was entered against the appellees on a declaration containing a count in contract and a count in tort. The trial judge found that all the parties in the case were negligent and finding the plaintiffs, appellants here, guilty of contributory negligence, a judgment was rendered in favor of the defendants, appellees.”

The Court of Appeals reversed the lower court and entered judgment for the home owner. Appellants find significant that Allied Oil Burner Services was held in as a co-defendant even though Mr. Dougherty installed the furnace and connected the flue pipe. It was Allied there which, like Metropolitan here, “undertook to install the oil tank, connect the oil line to the burner, run the filling vent, prime the pump, start the burner, adjust the fire, and check the fan and safety controls.” Id. at 29-30.

While agreeing with appellants that Klein is remarkably similar factually, we find it readily distinguishable. The primary, if not sole, concern of the Court of Appeals in Klein was whether the. owner-contractor was contributorily [603]*603negligent. In that regard, while holding that there was no obligation on the part of Mr. Klein to specifically instruct Mr. Dougherty in the installation, the Court said “We also see no obligation on the part of Mr. Klein to have inspected to see whether Allied had properly turned on the furnace.” Id. at 30.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Hagan v. Washington Suburban Sanitary Commission
314 A.2d 699 (Court of Special Appeals of Maryland, 1974)
Miller v. Michalek
281 A.2d 117 (Court of Special Appeals of Maryland, 1971)
Otis Elevator Co. v. Embert
85 A.2d 876 (Court of Appeals of Maryland, 1951)
Lauer v. Scott
280 A.2d 917 (Court of Special Appeals of Maryland, 1971)
Belleson v. Klohr
264 A.2d 274 (Court of Appeals of Maryland, 1970)
Buchanan v. Galliher
272 A.2d 814 (Court of Special Appeals of Maryland, 1971)
Klein v. Dougherty
87 A.2d 821 (Court of Appeals of Maryland, 1952)
Montgomery Ward & Co. v. McFarland
319 A.2d 824 (Court of Special Appeals of Maryland, 1974)
Burns v. Goynes
290 A.2d 165 (Court of Special Appeals of Maryland, 1972)
MacPherson v. . Buick Motor Co.
111 N.E. 1050 (New York Court of Appeals, 1916)

Cite This Page — Counsel Stack

Bluebook (online)
334 A.2d 553, 25 Md. App. 598, 1975 Md. App. LEXIS 553, Counsel Stack Legal Research, https://law.counselstack.com/opinion/morgan-v-metropolitan-fuels-inc-mdctspecapp-1975.