L & S Framing Inc. v. Cal. Occupational Saf. & Health Appeals Bd.

CourtCalifornia Court of Appeal
DecidedJuly 24, 2023
DocketC096386
StatusPublished

This text of L & S Framing Inc. v. Cal. Occupational Saf. & Health Appeals Bd. (L & S Framing Inc. v. Cal. Occupational Saf. & Health Appeals Bd.) is published on Counsel Stack Legal Research, covering California Court of Appeal primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
L & S Framing Inc. v. Cal. Occupational Saf. & Health Appeals Bd., (Cal. Ct. App. 2023).

Opinion

Filed 6/29/23; Certified for Publication 7/24/23 (order attached)

IN THE COURT OF APPEAL OF THE STATE OF CALIFORNIA THIRD APPELLATE DISTRICT (Placer) ----

L & S FRAMING INC., C096386

Plaintiff and Appellant, (Super. Ct. No. SCV0046603)

v.

CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH APPEALS BOARD,

Defendant and Respondent;

CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS,

Real Party in Interest and Respondent.

On August 20, 2016, Martin Mariano, an employee of plaintiff L & S Framing Inc., was working on a residential house under construction when he fell from the second floor onto the concrete ground floor below, sustaining serious injuries. Following an investigation, real party in interest California Department of Industrial Relations’

1 Division of Occupational Safety and Health (the Division) issued a notice of intent to cite plaintiff and subsequently issued a citation, which eventually included a serious accident- related citation for violation of California Code of Regulations, title 8, section 1626, subdivision (b)(5). 1 Plaintiff appealed the citation. An administrative law judge (ALJ) denied the Division’s mid-hearing request to amend the citation to allege a violation of section 1632, subdivision (b)(1), denied the Division’s post-hearing motion to amend to allege violation of section 1626, subdivision (a)(2), and concluded the Division failed to prove the alleged violation of section 1626, subdivision (b)(5). The Division filed a petition for reconsideration with the defendant California Occupational Safety and Health Appeals Board (the Appeals Board). The Appeals Board concluded the ALJ improperly denied the two requests to amend and upheld the citation based on violation of both section 1632, subdivision (b)(1) and 1626, subdivision (a)(2). Plaintiff filed a petition for a writ of mandate in the trial court, the trial court denied the petition, and plaintiff appeals. Plaintiff asserts the trial court (1) erred in permitting the Appeals Board to amend the citation, (2) incorrectly concluded sections 1632, subdivision (b)(1) and 1626, subdivision (a)(2) applied, and (3) incorrectly concluded section 1716.2 did not apply and did not supersede the other regulations on the facts of this case. The second and third of these contentions depend on the seemingly simple question whether the specific location from which Mariano fell qualified as a floor opening (§ 1632, subd. (b)(1)) and/or a stairwell (§ 1626, subd. (a)(2)), or instead an “unprotected side[] or edge[]” (§ 1716.2, subd. (f)). We affirm. We conclude the Appeals Board properly allowed the Division to amend the citation, the Appeals Board reasonably deemed the location at issue to fall

1 Further undesignated citations are to sections in title 8 of the California Code of Regulations.

2 within the scope of sections 1632 subdivision (b)(1) and 1626, subdivision (a)(2) and that determination was supported by substantial evidence, and the Appeals Board properly determined section 1716.2 did not apply. BACKGROUND The Accident On August 20, 2016, plaintiff’s employees were working in a subdivision called Highland Grove. Mariano worked for plaintiff and was on the crew working on unit number 49. At that location, a stairway had been built from the ground floor to the second floor. The U-shaped stairway consisted of three segments of stairs. The first segment was to the right as one entered the front door and led part way up from the ground floor. The second segment turned 90 degrees to the left of the first and continued upwards. The third again turned 90 degrees to the left and continued upward until it connected with the second floor. The lowest segment of stairs starting on the ground floor abutted the wall containing the entry door. As they constructed the stairs, plaintiff’s employees also built wooden railings. After the floor on the second floor was covered with plywood decking, but before exterior walls were erected, workers assembled wooden railings around the open edges. At the top of the stairs on the second floor, there was an L-shaped floor space leading away from the stairs and then perpendicularly 90 degrees to the left. Wooden railings or handrails on each of the two sides were erected after the flooring was put down, one along the landing at the stop of the stairs and another extending perpendicularly to the left for several feet until it met the framing of a wall. But for the railing extending to the left, the floor would have led into an open space above the interior area of the house’s ground floor. At least one witness referred to that railing

3 alternately as a railing and a wall. 2 Testimony indicated that, at some point, that railing was to be replaced with, or perhaps completed as, a short interior wall approximately 36 inches high. Once completed, one would be able to see the house’s “volume ceiling” from the second-floor “bonus room” over that short wall. On the day of the accident, Mariano was on the second floor doing wall installation. The workers removed the railing or handrail that was where the short wall would ultimately be erected because they were working on an exterior wall which they had to lay down on the floor of the bonus room in order to work on it. It would not fit on the floor with the handrail in place. Mariano was “chalking the strap line with his back towards the unguarded stairwell (inaudible) and he fell to the [first] floor.” Mariano fell 10 feet four inches to the concrete floor on the ground floor below. He sustained a brain injury characterized as a serious injury. The Division Issues Citations Ronald Aruejo, a senior safety engineer for the Division, issued plaintiff three general citations and one serious accident-related citation. Only the serious accident- related citation is at issue here. Before issuing the serious accident-related citation, Aruejo sent a notice of intent. The notice of intent, Cal/OSHA form 1BY (1BY), cited an alleged violation of one of the Division’s Construction Safety Orders. (§ 1502 et seq.) Specifically, the 1BY alleged a violation of section 1626, subdivision (a)(2), although it also stated the alleged violation

2 Plaintiff insists this was not a railing but the framing of a short wall, and the fact that witnesses referred to it as a railing did not convert the skeletal framing of the short wall into a railing. Whether this structure was a temporary railing or the structural framing for a short wall ultimately is immaterial. The relevant issues are the definition of the space where the railing or wall was located and the fact that it was removed, leaving that space where Mariano fell unguarded.

4 “may be cited as a violation” of that section “or any other applicable regulation.” The 1BY recited, in part: “[T]he employer did not provide railings and toe boards meeting the requirements of Article 16 around the stairwell of a story [sic] residential building under construction. As a result, an employee was seriously injured when he fell from the open side of the stairwell and landed approximately 11 feet below onto a concrete floor.” The subsequent citation itself set forth the following: “[T]he employer did not provide the exposed sides of a stairway with temporary railings and toe board as prescribed in Section 1620. As a result, an employee was seriously injured when he fell from the exposed side of the stairway and landed approximately 11 feet below onto a concrete floor.” The citation cited section 1626, subdivision (a)(5). According to Aruejo, the language in the citation was from section 1626, subdivision (b)(5), and the reference to a nonexistent subdivision (a)(5) was a typographical error. The citation sets forth verbatim the language appearing in section 1626, subdivision (b)(5). That subdivision provides: “Unprotected sides and edges of stairway landings shall be provided with railings.

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Gaehwiler v. Occupational Safety & Health Appeals Board
141 Cal. App. 3d 1041 (California Court of Appeal, 1983)
Neighbours v. Buzz Oates Enterprises
217 Cal. App. 3d 325 (California Court of Appeal, 1990)
Davey Tree Surgery Co. v. Occupational Safety & Health Appeals Board
167 Cal. App. 3d 1232 (California Court of Appeal, 1985)
Alcala v. Western Ag Enterprises
182 Cal. App. 3d 546 (California Court of Appeal, 1986)
Conolley v. Bull
258 Cal. App. 2d 183 (California Court of Appeal, 1968)
Overaa Construction v. California Occupational Safety & Health Appeals Board
54 Cal. Rptr. 3d 154 (California Court of Appeal, 2007)
Garcia v. Roberts
173 Cal. App. 4th 900 (California Court of Appeal, 2009)
Reichardt v. Hoffman
52 Cal. App. 4th 754 (California Court of Appeal, 1997)
Rick's Electric, Inc. v. California Occupational Safety & Health Appeals Board
95 Cal. Rptr. 2d 847 (California Court of Appeal, 2000)
People v. Dove III
21 Cal. Rptr. 3d 52 (California Court of Appeal, 2004)
Hammond v. Agran
90 Cal. Rptr. 2d 876 (California Court of Appeal, 1999)
Mendoza v. Rast Produce Co., Inc.
45 Cal. Rptr. 3d 525 (California Court of Appeal, 2006)
Wasatch Property Management v. Degrate
112 P.3d 647 (California Supreme Court, 2005)
Carmona v. Division of Industrial Safety
530 P.2d 161 (California Supreme Court, 1975)
Elsner v. Uveges
102 P.3d 915 (California Supreme Court, 2004)
Allen v. City of Sacramento
234 Cal. App. 4th 41 (California Court of Appeal, 2015)

Cite This Page — Counsel Stack

Bluebook (online)
L & S Framing Inc. v. Cal. Occupational Saf. & Health Appeals Bd., Counsel Stack Legal Research, https://law.counselstack.com/opinion/l-s-framing-inc-v-cal-occupational-saf-health-appeals-bd-calctapp-2023.