Amco Und. of Audubon Ins. Co. v. AMERICAN RADIATOR & S. CORP.

329 So. 2d 501, 1976 La. App. LEXIS 4126
CourtLouisiana Court of Appeal
DecidedMarch 1, 1976
Docket10626
StatusPublished
Cited by18 cases

This text of 329 So. 2d 501 (Amco Und. of Audubon Ins. Co. v. AMERICAN RADIATOR & S. CORP.) is published on Counsel Stack Legal Research, covering Louisiana Court of Appeal primary law. Counsel Stack provides free access to over 12 million legal documents including statutes, case law, regulations, and constitutions.

Bluebook
Amco Und. of Audubon Ins. Co. v. AMERICAN RADIATOR & S. CORP., 329 So. 2d 501, 1976 La. App. LEXIS 4126 (La. Ct. App. 1976).

Opinion

329 So.2d 501 (1976)

AMCO UNDERWRITERS OF the AUDUBON INSURANCE COMPANY
v.
AMERICAN RADIATOR AND STANDARD CORPORATION et al.

No. 10626.

Court of Appeal of Louisiana, First Circuit.

March 1, 1976.

Iddo Pittman, Jr., Hammond, for appellant.

Ernest L. O'Bannon, New Orleans, for appellees.

Before ELLIS, BLANCHE and LOTTINGER, JJ.

BLANCHE, Judge.

Defendants-appellants, American Radiator and Standard Corporation, Aetna Casualty and Surety Company, and Tappan Company, appeal the granting of a subrogation claim to plaintiff-appellee, Amco Underwriters of the Audubon Insurance Company, for a fire loss that plaintiff paid to their insured, Dorchester Webb.

Judgment was rendered against the defendants, in solido, for $8,334.54, together with interest at the rate of 7 percent per annum from date of judicial demand until *502 paid, and for all costs, including expert witness fees in the sum of $300. From this judgment, all defendants have appealed. We affirm.

The home of Dorchester Webb, located in Slidell, St. Tammany Parish, Louisiana, was damaged by fire on December 16, 1972. Webb was the first occupant of the subject house, having purchased it in 1965. At the time of the sale the house was not completely finished. Some work remained to be done in the kitchen, and the heating unit was not connected to its butane fuel source. The pipes with which to connect the unit to the fuel source were present but had never been connected.

Webb decided to use natural gas instead of butane, and since he was a construction worker and familiar with plumbing, he changed the gas orifices so that the unit would burn natural gas. He then connected the heater unit with the natural gas source himself, bypassing the pipes which were originally installed for butane.

The unit's thermostat and a required "on-off" switch were located in the hallway of the house. The power switch, when in the "off" position, completely terminated all electricity flowing to the heating unit. However, the pilot light, which burned natural gas, would continue to burn even though the power switch was in the "off" position.

Webb and his family exclusively used the "on-off" switch rather than the thermostat to control the unit.

On the morning of the fire, Mrs. Webb routinely turned the power switch to the "off" position in preparation for a shopping trip in Slidell. However, her automobile would not start, and she and her daughter returned to the house to drink coffee and prepare to decorate the house for Christmas. A short while later her attention was drawn to loud noises in the attic which she investigated and discovered that the heating unit was on fire.

The plaintiff's expert electrical and mechanical engineer, Joseph E. Leininger, testified that the solenoid gas valve regulating the entry of the gas into the combustion chamber of the heater did not fully close when Mrs. Webb de-energized the unit by turning the power switch off. The valve allowed gas to pass into the chamber where it was ignited by the pilot. As a result of the power being off, the blower fan did not activate to blow the heated air out of the chamber, through the heating ductwork and into the house. As a consequence of the fan's failure to blow the hot air from the combustion chamber, the heat therein became so intense that it ignited the supporting rafters, resulting in the damage complained of.

The defendants' heating technician, Kenneth E. Varndell, agreed with Leininger's theory concerning the origin of the fire. Varndell was not an engineer and was not tendered as an expert to the court.

The valve in question was removed by the plaintiff subsequent to the fire and examined by Leininger, but he could not ascertain the exact reason the valve would not seat properly. Varndell never examined the valve because it was lost by Leininger subsequent to his examination thereof.

Defendants denied liability for the fire, and alternatively contended that the plaintiff was barred from recovery by the contributory negligence of their insured. In an attempt to prove that Webb was contributorily negligent in installing the subject unit, the defendants' witness, Varndell, pointed out that this particular unit was not one which could readily be adapted to natural gas. In addition to the change of orifice performed by Webb, the unit required a pressure regulator to adjust for the difference in pressure between natural gas and butane, and also required a "drip leg" to remove moisture from the gas. Webb did not install either a regulator or drip leg.

*503 Varndell contended that the malfunction of the valve could have been caused by the fact that the pressure was not regulated and/or by moisture contained in the natural gas since no drip leg was installed.

Varndell's testimony for the defendants clearly established that the subject unit should be turned on and off only by the thermostat. The company recommends cutting the electricity off in the manner routinely done by the Webbs only to service the unit or in an emergency. The reason for this recommendation is that the fan, which blows the heated air from the combustion chamber and thereby prevents it from overheating, will not activate when the power is off. However, when the power is on, the rise of temperature from such an occurrence as herein will activate the fan and heated air is blown into the house. The heated air would continue to be blown into the house until such time as the occupants became overheated and checked the unit. This action of the fan is, therefore, a built-in safety feature of the unit.

Varndell acknowledged that a power cut-off switch such as that utilized by the Webbs is required by virtually all safety codes and that his company recommends it to be close to the unit itself.

However, Varndell also acknowledged that there are no instructions in the manual for this particular unit which would put the user on notice that the described "on-off" switch should not be used to operate the unit. It is uncontradicted that the homeowner in the instant case was not aware that by turning the power to the unit off he was destroying one of the safety features of the unit, that is, the fan's automatic response to elevated temperature in the combustion chamber.

Without passing on the question of the homeowner's contributory negligence, the trial judge found that the malfunction of the valve was not the cause of the fire. He concluded that the "cause" of this fire was Mrs. Webb's use of the electrical power switch to turn off the heating unit, which, in turn, deactivated the fan motor, thereby eliminating one of the unit's safety features.

After reaching his conclusion concerning the cause of the fire, the trial judge found that the defendants had a duty to warn users of the unit concerning the danger of using the power switch to control the unit and, therefore, held defendants liable for the damage resulting from their failure to so warn.

There is little doubt but that the leaking valve was a substantial factor without which the fire would not have occurred. Therefore, it was one cause-in-fact of the plaintiff's loss. Dixie Drive It Yourself System v. American Beverage Company, 242 La. 471, 137 So.2d 298 (1962).

There also can be little doubt but that the failure of the described safety feature, that is, the fan's automatic response to elevated temperature in the combustion chamber, was likewise a substantial factor and an additional cause-in-fact of the plaintiff's loss. Dixie, supra.

Therefore, the first issue on this appeal is:

Free access — add to your briefcase to read the full text and ask questions with AI

Related

Hines v. Remington Arms Co., Inc.
648 So. 2d 331 (Supreme Court of Louisiana, 1994)
Sawyer v. NIAGARA MACH. AND TOOL WORKS, INC.
535 So. 2d 1057 (Louisiana Court of Appeal, 1988)
Winterrowd v. Travelers Indem. Co.
452 So. 2d 269 (Louisiana Court of Appeal, 1984)
Walker v. Preformed Line Products Co.
600 F. Supp. 280 (W.D. Louisiana, 1984)
Shelby Bridges v. Chemrex Specialty Coatings, Inc.
704 F.2d 175 (Fifth Circuit, 1983)
Pawlak v. Brown
430 So. 2d 1346 (Louisiana Court of Appeal, 1983)
Benoit v. Ryan Chevrolet
428 So. 2d 489 (Louisiana Court of Appeal, 1983)
Woods ex rel. Woods v. International Harvester Co.
697 F.2d 635 (Fifth Circuit, 1983)
Woods v. International Harvester Company
697 F.2d 635 (Fifth Circuit, 1983)
Joseph v. Albarado
407 So. 2d 1277 (Louisiana Court of Appeal, 1981)
Hebert v. Brazzel
403 So. 2d 1242 (Supreme Court of Louisiana, 1981)
Hines v. Dixie Electric Membership Corp.
391 So. 2d 1203 (Louisiana Court of Appeal, 1980)
Poland v. Beaird-Poulan
483 F. Supp. 1256 (W.D. Louisiana, 1980)
Fincher v. Surrette
365 So. 2d 860 (Louisiana Court of Appeal, 1978)
Chappuis v. Sears Roebuck & Co.
349 So. 2d 963 (Louisiana Court of Appeal, 1977)
Foster v. Marshall
341 So. 2d 1354 (Louisiana Court of Appeal, 1977)

Cite This Page — Counsel Stack

Bluebook (online)
329 So. 2d 501, 1976 La. App. LEXIS 4126, Counsel Stack Legal Research, https://law.counselstack.com/opinion/amco-und-of-audubon-ins-co-v-american-radiator-s-corp-lactapp-1976.